1. Installation
1−10
Festo P.BE−CP−SD8−...−EN en 0503b
Please note
Station numbers may only be assigned once for each field
bus line.
Recommendation:
Assign the station numbers in ascending order. If necessary,
adapt the assignment of the station numbers to suit the ma
chine structure of your system.
1.2.6 Setting the baud rate with manual mode
With manual mode the CPV valve terminal with direct connec
tion for the Smart Distributed supports the following baud
rates:
1
125 KBaud
2
250 KBaud
3
500 KBaud
1
2
3
Fig.1/6: Setting the baud rate with manual mode