Contents and general safety instructions
Festo GDCP-CMXR-C2-HW-EN 1002NH
11
Safety instructions
The documentation includes the information required for assembling the multi-axis
control system CMXR-C2 and for installing the central module.
Knowing and implementing perfectly the information contained in the documents is a
requirement for the successful planning and safe installation, commissioning, operation
and maintenance of control systems. Only qualified personnel have the required
specialised knowledge to correctly interpret and implement the instructions contained in
these documents.
The documentation cannot take every conceivable application into consideration. Should
you require additional information, then please ask for this at your nearest Festo branch.
During installation, commissioning and maintenance work, please observe the documen-
tation appurtenant to your multi-axis control system.
The documents are intended for
qualified personnel
. These are persons who have
appropriate knowledge in the area of automation technology relevant to their field of
activity.
Safety instructions on handling
When in a dismantled state, the modules used in the system are sensitive to electro-static
discharge.
Caution
Sub-assemblies and modules may be damaged if they are not
handled correctly.
Do not touch any components.
Observe the handling specifications for electrostatically
sensitive devices.
To protect the modules against discharges of static electricity:
Discharge yourself of static electricity before fitting or removing
the modules.
Caution
Destruction of modules and damage to the CMXR-C2 central control
unit
Switch off the supply voltages before you mount or remove
modules.
Install the device into a suitable control cabinet
(see section 2.3).