9. Service functions and error messages
96
Festo P.BE-CMMP-AS-3A-HW-EN 0708NH
Error message
Meaning of error message
Measures
Main index
Main
index
Sub-
index
2
PROFIBUS communication error Check the configured slave address.
Check the bus termination.
Check cabling.
3
PROFIBUS:
Invalid slave address
Communication was started with slave address 126.
Select a different slave address.
4
PROFIBUS:
Value range error
Mathematical error when converting physical units.
Value range of the data and the physical units do not
match. Contact Technical Support
25
0
Invalid device type
Error cannot be self-corrected.
Send the servo controller to your sales partner.
1
Unsupported device type
2
Unsupported HW version
Check the firmware version, if necessary,
request an update from Technical Support.
3
Device functionality limited!
Device is not enabled for the desired functionality and
may need to be enabled by Festo. The device must be
sent to Festo for this.
26
0
Missing user parameter record
Load the default parameter record.
If the error persists, send the servo positioning control-
ler to your sales partner.
1
Checksum error
Error cannot be rectified independently.
Please contact Technical Support.
2
Flash: Write error
3
Flash: Deletion error
4
Flash: Internal Flash error
5
Missing calibration data
6
Missing user position data re-
cord
Set the position and save it in the servo positioning
controller.
7
Error in the data tables (CAM)
Load the default parameter record, if necessary, reload
the parameter record.
If the error persists, contact Technical Support.
27
0
Contouring error danger thresh-
old
Check the contouring error parameterising.
Motor blocked?
28
0
Missing hours-run meter
Acknowledge the error.
If the error persists, contact Technical Support.
1
Hours-run meter: Write error
2
Hours-run meter corrected
3
Hours-run meter converted
30
0
Internal conversion error
Please contact Technical Support.
31
0
I²t motor
Motor blocked?
1
I²t servo positioning controller
Check power dimensioning of drive package.
Summary of Contents for CMMP-AS-C2-3A
Page 2: ......