6. Mechanical installation
Festo P.BE-CMMP-AS-3A-HW-EN 0708NH
59
6.
Mechanical installation
6.1
Important instructions
Note
Use the CMMP-AS servo positioning controller as an integrated
device for control cabinet assembly only.
The mounting position is vertical with the power supply lines
[X9] leading upwards.
Mount the clip on the control cabinet plate.
Mounting clearance:
For sufficient ventilation, 100 mm of clearance to other assem-
blies is required above and below the device.
The servo positioning controllers of the CMMP-AS family are
designed to be mounted on a heat-dissipating mounting panel
if used as intended and installed correctly. We wish to point out
that excessive heating can lead to premature aging and/or
damage to the device. With high thermal loads on the CMMP-AS
servo positioning controller, a mounting clearance of more than
71 mm is recommended!
-
Higher thermal loading requires more clearance