55
NOTES:
Values valid for
IP
and
IR
units,
STANDARD, LOw NOISE
and
EXTRA LOw NOISE
unit,
wITH
or
wITHOUT
hydronic kit.
FLA=
Full load current at maximum tolerated conditions
LRA=
Locked rotor current
FLI=
Full load power input at maximum tolerated conditions
MIC=
Maximum instantaneous current of the unit
Values relative to a
400V~3~50Hz
power supply voltage rating
ELECTRICAL CONNECTIONS
Specifications of pumping module accessory MP AM STD and MP SS STD
Specifications of pumping module accessory High working head MP AM HP1 and MP SS HP1
Summary tables (total values):
Specifications of pumping module accessory MP PS STD
Units without pumping module
UNIT
350.5
390.6
440.6
490.6
560.6
630.6
UM
Total maximum load current [ FLA ]
287
302
355
399
451
494
A
Total maximum power input [ FLI ]
171
182
211
237
272
304
kW
Total maximum starting current [ MIC ]
538
529
605
649
771
815
A
Units with pumping module MP PS STD (1 or 2 pumps)
Total maximum load current [ FLA ]
299
314
376
420
472
515
A
Total maximum power input [ FLI ]
178
189
224
250
285
317
kW
Total maximum starting current [ MIC ]
550
541
626
670
792
835
A
Units with pumping module MP AM STD and MP SS STD (1 or 2 pumps)
Total maximum load current [ FLA ]
301
316
376
420
472
515
A
Total maximum power input [ FLI ]
179
190
224
250
285
317
kW
Total maximum starting current [ MIC ]
552
543
626
670
792
835
A
Units with pumping module
MP AM HP1 and MP SS HP1
(1 or 2 pumps)
Total maximum load current [ FLA ]
308
323
382
426
478
521
A
Total maximum power input [ FLI ]
184
195
227
253
288
320
kW
Total maximum starting current [ MIC ]
558
550
632
676
798
842
A
Summary Fan specifications
UNIT
350.5
390.6
440.6
490.6
560.6
630.6
UM
Power supply
400 - 3 - 50
V-ph-Hz
FLA
AB
34.4
43.0
51.6
A
LRA
AB
120
150
180
A
FLI
AB
16.0
20.0
24.0
kW
UNIT
350.5
390.6
440.6
490.6
560.6
630.6
UM
Power supply
400 - 3 - 50
V-ph-Hz
FLA
AB
12.0
12.0
20.8
20.8
20.8
20.8
A
LRA
AB
96.0
96.0
166.4
166.4
166.4
166.4
A
FLI
AB
7.0
7.0
13.0
13.0
13.0
13.0
kW
UNIT
350.5
390.6
440.6
490.6
560.6
630.6
UM
Power supply
400 - 3 - 50
V-ph-Hz
FLA
AB
14.0
14.0
20.8
20.8
20.8
20.8
A
LRA
AB
112.0
112.0
166.4
166.4
166.4
166.4
A
FLI
AB
8.2
8.2
13.0
13.0
13.0
13.0
kW
UNIT
350.5
390.6
440.6
490.6
560.6
630.6
UM
Power supply
400 - 3 - 50
V-ph-Hz
FLA
AB
20.8
20.8
20.8
20.8
20.8
27.0
A
LRA
AB
166.4
166.4
166.4
166.4
166.4
216
A
FLI
AB
13.0
13.0
13.0
13.0
13.0
16.0
kW
Single Fan specifications
UNIT
350.5
390.6
440.6
490.6
560.6
630.6
UM
Power supply
400 - 3 - 50
V-ph-Hz
FLA
AB
4.3
A
LRA
AB
15.0
A
FLI
AB
2.0
kW