70
EN
Cod. 3541T090 - Rev. 00 - 06/2019
BOILER CONTROLLER - SERVICE MENU
0=Disattivato
Descrizione
Range
Default
b12
Modulation delta (b01=1)
0-30°C/10
0°C/10
Priority override - Activation (b01=2)
0-255 minutes
30 minutes
Modulation delta (b01=3)
0-30°C/10
0°C/10
Priority override - Activation (b01=4)
0-255 minutes
30 minutes
b13
Not implemented (b01=1)
--
--
Priority override - Deactivation (b01=2)
0-255 minutes
15 minutes
Not implemented (b01=3)
--
--
Priority override - Deactivation (b01=4)
0-255 minutes
15 minutes
b14
Pump antiblock operation time
0-20 seconds
5 seconds
b15
Flowmeter type selection (b01=1)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190 imp/l)
2= Flowmeter (190 imp/l)
No effect on adjustment (b01=2)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190 imp/l)
2= Flowmeter (190 imp/l)
Flowmeter type selection (b01=3)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190 imp/l)
2= Flowmeter (190 imp/l)
No effect on adjustment (b01=4)
0=Flow. (450 imp/l), 1=Flow. (700 imp/l), 2= Flow. (190 imp/l)
2= Flowmeter (190 imp/l)
b16
Fan frequency in standby mode
0-100%
0%
b17
Summer/Winter symbol
0 = Disabled, 1 = Enabled
0 = Disabled
b18
DHW mode activation flow rate (b01=1)
0-100L/min/10
25
No effect on adjustment (b01=2)
0-100L/min/10
25
DHW mode activation flow rate (b01=3)
0-100L/min/10
25
No effect on adjustment (b01=4)
0-100L/min/10
25
b19
DHW mode deactivation flow rate (b01=1)
0-100L/min/10
20
No effect on adjustment (b01=2)
0-100L/min/10
20
DHW mode deactivation flow rate (b01=3)
0-100L/min/10
20
No effect on adjustment (b01=4)
0-100L/min/10
20
b20
Flue material selection
0=Standard, 1=PVC, 2=CPVC
0=Standard
b21
PVC flue maximum temperature
60-110°C
88°C
b22
CPVC flue maximum temperature
60-110°C
93°C
b23
Standard flue shutdown maximum temperature
60-110°C
100°C
b24
PVC flue shutdown maximum temperature
60-110°C
93°C
b25
CPVC flue shutdown maximum temperature
60-110°C
98°C
b26
Flow temperature limit in automatic calibration
25°C ÷ 55°C
30°C
b27
Maximum temperature during calibration in DHW mode
75°C ÷ 95°C
80°C
b28
Flowmeter sensitivity factor
0 ÷ 60 (0 = disabled)
20
b29
Restoring Factory Values
Change the value from 0 to 10 by pressing the “DHW +” button. Confirm
by pressing the “h” button.
-
P30
Heating ramp
1-20°C/minute
4°C/minute
P31
Virtual setpoint min. temperature (b01=1)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature (b01=2)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature (b01=3)
0=Deactivated, 1-80°C
0=Deactivated
Virtual setpoint min. temperature (b01=4)
0=Deactivated, 1-80°C
0=Deactivated
P32
Heating standby time
0-10 minutes
4 minutes
P33
Heating Post-Circulation
0-255 minutes
15 minutes
P34
Pump operation
0-3 = Operation strategy
2
P35
Modulating pump min. speed
30-100%
30%
P36
Modulating pump start speed
90-100%
90%
P37
Modulating pump max. speed
90-100%
100%
P38
Pump deactivation temperature during Post-Circulation (b01=1) 0-100°C
50°C
Pump deactivation temperature during Post-Circulation (b01=2) 0-100°C
55°C
Pump deactivation temperature during Post-Circulation (b01=3) 0-100°C
55°C
Pump deactivation temperature during Post-Circulation (b01=4) 0-100°C
55°C
P39
Pump activation hysteresis temperature during Post-Circulation
(b01=1)
0-100°C
10°C
Pump activation hysteresis temperature during Post-Circulation
(b01=2)
0-100°C
25°C
Pump activation hysteresis temperature during Post-Circulation
(b01=3)
0-100°C
25°C
Pump activation hysteresis temperature during Post-Circulation
(b01=4)
0-100°C
25°C
P40
Heating user max. setpoint
20-90°C
80°C
P41
Max. output in heating
0-100%
80%
P42
Burner shutdown in DHW (b01=1)
0=Fixed, 1=Linked to setpoint, 2=Solar
0=Fixed
Legionella protection (b01=2)
0-7=Days of activation (1 = Once every 24 hours / 7= Once every 168
hours)
0=No protection
Burner shutdown in DHW (b01=3)
0=Fixed, 1=Linked to setpoint, 2=Solar
0=Fixed
Legionella protection (b01=4)
0-7=Activation days
0=No protection
P43
Comfort activation temperature (b01=1)
0-50°C
40°C
Storage tank hysteresis (b01=2)
0-60°C
2°C
Comfort activation temperature (b01=3)
0-80°C
40°C
Storage tank hysteresis (b01=4)
0-60°C
2°C
P44
Not used (b01=1)
Do not modify
0
Primary setpoint (b01=2)
70-85°C (Primary circuit temperature adjustment in DHW)
80°C
Comfort deactivation hysteresis (b01=3)
0-20°C
20°C
Primary setpoint (b01=4)
70-85°C (Primary circuit temperature adjustment in DHW)
80°C
P45
DHW standby time (b01=1)
30-255 seconds
60 seconds
DHW standby time (b01=2)
30-255 seconds
120 seconds
DHW standby time (b01=3)
30-255 seconds
120 seconds
DHW standby time (b01=4)
30-255 seconds
120 seconds
P46
DHW user max. setpoint (b01=1)
40-70°C
55°C
DHW user max. setpoint (b01=2)
40-70°C
65°C
DHW user max. setpoint (b01=3)
40-70°C
55°C
DHW user max. setpoint (b01=4)
40-70°C
65°C
P47
DHW pump Post-Circulation (b01=1)
0-255 seconds
50 seconds
DHW pump Post-Circulation (b01=2)
0-255 seconds
30 seconds
DHW pump Post-Circulation (b01=3)
0-255 seconds
30 seconds
DHW pump Post-Circulation (b01=4)
0-255 seconds
30 seconds
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...