59
EN
Cod. 3541T090 - Rev. 00 - 06/2019
REMOTE CONTROLLER - SERVICE MENU
When the cursor is on OPERATE PREHEATING FOR FLOOR, Use ◄ ► to scroll
to YES and press OK. The page will be displayed as follows:.
12.2 PREHEATING FOR FLOOR
Preheat for floor is
running for 25 minutes.
Water flow temperature is 20
°C.
CONFIRM
OK
fig. 135 -
During preheating for floor, all the buttons except OK are invalid. If you want to turn
off the preheating for floor, please press OK. The following page will be displayed:
12.2 PREHEATING FOR FLOOR
Do you want to turn of the
preheating for floor function?
SCROLL
CONFIRM
OK
NO
YES
fig. 136 -
Use ◄ ►to scroll the cursor to YES and press OK, the preheating for floor will
turn off.
Before floor heating, if large a amount of water remains on the floor, the floor may
be warped or even rupture during floor heating operation, in order to protect the
floor, floor drying is necessary, during which the temperature of the floor should
be increased gradually.
If FLOOR DRYING UP is selected, after press OK ,the page will displayed as
follows:.
12.3 FLOOR DRYING UP
WARM UP TIME(t_DRYUP)
KEEP TIME(t HIGHPEAK)
PEAK TEMP. (T_DRYPEAK)
START TIME
START DATE
8 days
5 days
45°C
15:00
01-05-2015
SCROLL
1/2
fig. 137 -
When the cursor is on WARM UP TIME (t_DRYUP), KEEP TIME (t_HIGHPEAK),
TEMP. DOWN TIME (t_DRYD), PEAK TEMP. (T_DRYPEAK), START TIME or
START DATA, Use ◄ ► and ▼ ▲ to scroll and adjust the parameter.
t_DRYUP is the day for warming up.
t_HIGHPEAK is the last day of high temperature.
t_DRYD is the day of dropping temperature
T_DRYPEAK is the target peak temperature of water flow during floor drying up.
The target outlet water temperature during floor drying up described
in the picture below:
t_DRYUP t_DRYPEAK
T1S
t
t_DRYD
T_DRYPEAK
fig. 138 -
When the cursor is on OPERATE FLOOR DRYING? Use ◄ ► to scroll to YES
and press OK. The page will be displayed as follows.
During floor drying, all
the buttons except OK are invalid. When the heat pump malfun-
ctions, the floor drying mode will turn off when the backup heater
and additional heating source is unavailable. If you want to turn
off floor drying up, please press OK. Use ◄ ◄ to scroll the cursor to
YES and press OK. Floor drying will turn off.
12.3 FLOOR DRYING UP
The unit will operate floor
drying on 09:00 16-12-2015.
CONFIRM
OK
fig. 139 -
8.15 Auto restart
The AUTO RESTART function is used to select whether the unit reapplies the user
interface settings at the time when power returns after a power supply.
Go to MENU> FOR SERVICEMAN> AUTO RESTART
Use ▼, ▲, ◄, ► to scroll and use OK to select YES or NON to enable or disable
the auto restart function. If the auto restart function is enabled, when power returns
after a power supply failure, the AUTO RESTART function reapplies the user in-
terface settings at the time of the power supply failure. If this function is disabled,
when power returns after a power supply failure, the unit won’t auto restart.
13 AUTO RESTART
DHW MODE
COOL/HEAT MODE
SCROLL
YES
YES
NO
NO
fig. 140 -
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...