44
EN
Cod. 3541T090 - Rev. 00 - 06/2019
REMOTE CONTROLLER - USER MENU
TIMER
WEEKLY SCHEDULE
SCHEDULE
12
:
30
01-01-2015
SCROLL
TIME
CURRENT TIME
CURRENT DAY
fig. 81 -
Use ‘’◄’’,’’►’’,’’▼’’,’’▲’’ to scroll and Use ‘’▲’’ ,’’▼’’ adjust the time and date.
☞
NOTE
■ The ECO MODE has the highest priority, the TIMER or WEEKLY SCHEDULE
has the second priority and the PRESET TEMP. or WEATHER TEMP. SET has
the lowest priority.
■ The PRESET TEMP. or WEATHER TEMP. SET becomes not active, when the
ECO is active. In this case it is necessary to reset the PRESET TEMP. or WEA-
THER TEMP. SET.
■ TIMER or WEEKLY SCHEDULE is not affected when ECO is active. TIMER or
WEEKLY SCHEDULE is activated when the ECO is not running.
■ TIMER and WEEKLY SCHEDULE have the same priority.
The
last
set function is active. The PRESET TEMP. becomes not active when TIMER or
WEEKLY SCHEDULE is active. The WEATHER TEMP. SET is not affected by the
setting of TIMER or WEEKLY SCHEDULE.
■ PRESET TEMP and WATHER TEMP.SET have the same priority. The last set
function is active.
7.12 Options
OPTIONS menu contents as following:
1)
SILENT MODE
2)
HOLIDAY AWAY
3)
HOLIDAY HOME
4)
BACKUP HEATER
SILENT MODE
The SILENT MODE is used to decrease the sound of the unit. However, it also
decreases the heating/cooling capacity of the system. There are two silent mode
levels.
Level 1 is more silent than level 2,and the heating or cooling capacity is also more
decreasing.
There are two method to use the silent mode:
1) silent mode in all time;
2) silent mode in timer.
■ Go to the home page to check if silent mode is activated. If
is displayed, If the silent mode is activated, will display on the home page.
■ Go to ‘’MENU’’ > ‘’OPTIONS’’ > ‘’SILENT MODE’’. Press ‘‘OK’’ . The following
page will appear:
HOLIDAY
AWAY
HOLIDAY
HOME
BACKUP
HEATER
OPTIONS
OFF
ENTER
SILENT
MODE
SCROLL
ADJUST
CURRENT STATE
SILENT LEVEL
TIMER
fig. 82 -
Use ‘‘ON/OFF’’ to select ON or OFF.
If CURRENT STATE is OFF, SILENT MODE is invalid.
When you select SILENT LEVEL, and press ‘’OK’’ or ‘’►’’. The following page will
appear:
LEVEL 1
HOLIDAY
AWAY
HOLIDAY
HOME
BACKUP
HEATER
OPTIONS
CURRENT STATE
SILENT LEVEL
TIMER
ON
ENTER
SILENT
MODE
SCROLL
ADJUST
LEVEL 2
HOLIDAY
AWAY
HOLIDAY
HOME
BACKUP
HEATER
OPTIONS
CURRENT STATE
SILENT LEVEL
TIMER
ON
ENTER
SILENT
MODE
SCROLL
ADJUST
LEVEL 1
LEVEL 2
fig. 83 -
You can use ‘’▼’’,’’▲’’ to select level 1 or level 2. Press ‘‘OK’’.
If the silent TIMER is selected, Press “OK” to enter, the following page will appear.
HOLIDAY
AWAY
HOLIDAY
HOME
BACKUP
HEATER
OPTIONS
SILENT
MODE
NO.
START
22:00
T1
T2
END
12:00
07:00
15:00
SCROLL
fig. 84 -
There are two timers for setting.Move to “■”, press ‘’ OK ‘’ to select or unselect.
If both time bands are unselected, the silent mode will operate in all time. Other-
wise, it will operate according to the time band.
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...