6.1 Inspections on arrival
Upon receipt of the unit it is essential to check that you have received all the material indicated on the accompanying document, and also that it has not been damaged
during transport. If so, have the dispatcher ascertain the extent of the damage suffered, alerting our customer management office in the meantime. Only by acting in
this way and in a timely manner will it be possible to have the missing material or compensation for damages.
Packing and storing
All machines are packed in cardboard boxes specific for each unit.
The indications required to correctly handle the appliance while storing and instal-
ling it are written on the packing.
The storage temperature must be between -25°C and 55°C.
☞
NOTA: Do not dispose of the packaging in the environment.
Do not dispose of, leave or leave within the reach of children the packaging mate-
rial as it may be a potential source of danger.
Once the place in which the unit is to be installed has been chosen (see the rela-
tive sections) proceed as follows to unpack the two units.
fig. 11 -
fig. 12 -
6.2 Selecting the installation site and minimum operating area indoor unit
The place of installation must be free of powders, flammable objects or materials
or corrosive gases.
The unit is designed for wall hanging installation and is equipped as standard with
a hooking bracket. The fixing to the wall must guarantee a stable and effective
support.
☞
For the dismantling of the paneling and for normal maintenance acti-
vities the minimum operating spaces must be respected.
Select an installation location where the following conditions are met:
- Place that allows to respect the maximum lengths allowed for pipes, connections
to the unit of temperature probes, remote control etc ..
- Do not place objects or equipment on top of the unit.
- Make sure that all the precautions and prescriptions foreseen by local laws and
regulations regarding possible refrigerant leaks are correctly applied.
- It is advisable to place the boiler for domestic hot water production as close as
possible to the indoor unit.
300
300
600
500
500
fig. 13 -
Summary of Contents for OMNIA HYBRID C
Page 34: ...34 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU 7 2 Menu structure ...
Page 35: ...35 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU DHW mode is setting OFF ...
Page 36: ...36 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER USER MENU ...
Page 51: ...51 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU ...
Page 53: ...53 EN Cod 3541T090 Rev 00 06 2019 REMOTE CONTROLLER SERVICE MENU U ...
Page 100: ...100 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Principle scheme ...
Page 101: ...101 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Electronic heat pump board ...
Page 102: ...102 EN Cod 3541T090 Rev 00 06 2019 ELECTRICAL DIAGRAM INDOOR UNIT Wiring board ...
Page 113: ...113 EN Cod 3541T090 Rev 00 06 2019 ...
Page 114: ...114 EN Cod 3541T090 Rev 00 06 2019 ...