BLUEHELIX MAXIMA
195
EN
cod. 3541U630 - Rev. 03 - 11/2020
Restoring system hydraulic pressure
The boiler provides for various ways of restoring the hydraulic system. pressure.
Manual
, always
available, or
semiautomatic
or
automatic
depending on the parameter value
P62
.
"Pressure control" screen
To access the pressure control screen, simply touch the pressure value (detail 4 - fig. 1) on the
main screen.
Description of "Pressure control" screen
fig. 8- Pressure control
Legend fig. 8
1
Back to main screen
2
Pressure status indicator (see attached
table)
3
Boiler operating pressure zone
4
Pressure zone too high (boiler blocked)
5
Current pressure indicator
6
Current pressure value
7
Pressure zone too low, boiler operation
inhibited
8
Pressure reset button (enabled in se-
miautomatic mode)
9
Nominal pressure indicator
Bar
01 Mar 2020 14:36
CONNECTED
1.2
32.5°
ON
28.5°
ON
02 Marzo 2020 14:36
CONNECTED
Controllo pressione
RIPRISTINA
0
0.4
2.8
4.0
Bar
1.1
Pressione ottimale!
9
5
6
3
4
8
2
1
Icon
Fault code Description
RED
F40
Pressure too high for boiler operation
YELLOW
F21
Pressure higher than nominal value
The boiler works at limited output
GREEN
NONE
Pressure at nominal value
YELLOW
F20
Pressure lower than nominal value
The boiler continues to work normally
RED
F37
Pressure too low for boiler operation
Summary of Contents for BLUEHELIX MAXIMA 24C