B01
is correctly set to
RRT
.
B09
Fault 20 status selection
Deactivated
Enabled
Enabled
B10
Not implemented
--
--
B11
Flowmeter timing
Deactivated
1s ÷ 10s
(seconds)
Deactivated
B12
Modulation Delta
0 ÷ 30°C/10
0°C/10
B13
Not implemented
--
--
B14
Pump antiblock operation
time
0 ÷ 20 seconds
5
B15
Flowmeter type selection
Flow. (450 imp/l)
Flow. (700 imp/l)
Flow (190 imp/l)
Flow (190 imp/l)
B16
Fan frequency in standby
mode
0 ÷ 100%
0%
B17
NOT IMPLEMENTED
--
B18
DHW mode activation flow
rate
0 ÷ 100L/min/10
25
B19
DHW mode deactivation
flow rate
0 ÷ 100L/min/10
20
B20
Flue material selection
0
= Standard
1
= PVC
2
= CPVC
0
B21
PVC flue maximum tempe-
rature
60 ÷ 110°C
88°C
B22
CPVC flue maximum tem-
perature
60 ÷ 110°C
93°C
B23
Standard flue shutdown
maximum temperature
60 ÷ 110°C
100°C
B24
PVC flue shutdown maxi-
mum temperature
60 ÷ 110°C
93°C
B25
CPVC flue shutdown maxi-
mum temperature
60 ÷ 110°C
98°C
B26
Flow temperature limit in
automatic calibration
25°C ÷ 55°C
30°C
B27
Maximum temperature
during calibration in DHW
mode
75°C ÷ 95°C
80°C
B28
Flowmeter sensitivity factor 0 ÷ 60 (0 = disabled)
20
B29
Restoring Factory Values
Set the value to 10
-
Code Description
Range
Default
P30
Heating ramp
1 ÷ 20°C/minute
4°C/minute
P31
Virtual set point min. tempe-
rature
0
= Deactivated
1 ÷ 80°C
0
Code Description
Range
Default