3.4 Troubleshooting
Diagnostics
During operation, the unit can generate two types of faults:
Type F
They indicate the presence of a temporary fault. They are not indicated, but are recorded
in the Service Menu faults history. If a type F fault is not resolved independently according
to specific safety criteria, it becomes a type A fault.
Type A
They indicate the presence of a blocking fault that requires user intervention to be resol-
ved. They are indicated by lighting up of the red LEDs, the appearance of a specific win-
dow on the screen, and by the presence of a red dot on the main menu icon.
Unblocking the boiler with type A fault in progress
When a type A fault is present, the boiler can be unblocked in two ways:
1 -
Touching [RESET] when a screen similar to that shown in fig. 33 appears.
2 -
Touching the main menu icon and then [Boiler Reset] when a screen similar to that shown
in fig. 34 (main menu icon with red dot) appears.
1
fig. 33
2
fig. 34
Bar
1.2
32.5°
ON
28.5°
ON
Bar
01 Mar 2020 14:36
CONNECTED
1.2
28.5°
ON
NASCONDI
RESET
Anomalia bloccante
14:09 01 Mar 2020
A01 / Mancata accensione del bruciatore
Bar
27 Mar 2020 14:36
CONNECTED
1.2
32.5°
ON
28.5°
ON
Jul 29 2020 14:36
CONNECTED
Impostazioni
Storico anomalie
2
Display
Blocca schermo
LED
Data e ora
Lingua
Diagnostica impianto
Reset Caldaia
Menu Service