TOGGLE / TIMER:
- OFF
:
Timed relay activation. Programmable between 1 and 600 seconds (default value: 5 seconds).
After a valid activation command, the BUS2 relay will remain active for the time programmed.
When programming the relay activation time, the counter begins at ‘0 seconds’, increasing with every ‘SEC,
10xSEC’ pressed.
To programme the activation time, follow the steps below:
1.-
Relay programming setup:
2.-
Programme activation time
· SEC
: Each press increases the activation
time by 1 second.
· 10xSEC
: Each press increases the
activation time by 10 seconds.
B
B
B B
BUS-2 OUTPUT
BUS-2 INPUT
led PRG
ACTV EXT
GND
INHAB/DISABLE
OUTPUT 12V 0.5A
MODULO RELE
BUS 2
REF. 3247
MADE IN SPAIN
GND
relay ON
+12V
NC
NO
C
RELAY MODUL
BUS 2
PRG
10xsec
sec
1 2
ON
3
1 2
ON
3
DSW1
TEST
CONFIG
DSW2
Press the BUS2 relay’s PRG
button. The red LED lights up and
flashes to indicate that it is in
programming mode.
PRG
Led
B
B
B B
BUS-2 OUTPUT
BUS-2 INPUT
led PRG
ACTV EXT
GND
INHAB/DISABLE
OUTPUT 12V 0.5A
MODULO RELE
BUS 2
REF. 3247
MADE IN SPAIN
GND
relay ON
+12V
NC
NO
C
RELAY MODUL
BUS 2
PRG
10xsec
sec
1 2
ON
3
1 2
ON
3
DSW1
TEST
CONFIG
DSW2
- ON
:
Relay activation in bistable mode (converted).
The relay switches its status with every activation.
EXTERNAL:
- ON
:
enables the activation of the
entry panel relay
in response to a ‘call from panel’ command (configured on
DWS2). This activation is additional to the activation of the BUS2 relay.
In ‘call from panel’ mode, when a call is made from the entry panel, in addition to activating the BUS2 relay, the
relay on the panel from which the call was made is activated (the timing of the panel amplifier relay depends on the
time programmed on the panel itself).
- OFF
: disables the entry panel relay’s activation function.
In ‘call from panel’ mode, when a call is made from the entry panel, only the BUS2 relay is activated.
ALL / PRG:
- ON (ALL)
: Any system device that sends a valid command (in accordance with that programmed on the
DWS2) activates the relay.
- OFF (PRG)
: The relay is only activated if the command received is valid and has been sent from a device
(telephone, monitor) on which the BUS2 address has been pre-programmed (registered).
The residential terminals are programmed with BUS2 addresses (call codes) ranging between 1 and 1999 (refer to
section ‘Residential Terminals’). The BUS2 relay allows the programming of addresses with activation authorisation,
so that the BUS2 relay can be linked to one sole device or a group of devices.
1.-
Relay programming setup:
2.-
Address allocation (call code)
Button panels
Keypad panels
Press the call button
linked to the device
(telephone/monitor) that
you wish to register.
Using the keypad, enter the call code
allocated to the device (telephone/
monitor) that you wish to register and
press ‘bell’.
B
B
B B
BUS-2 OUTPUT
BUS-2 INPUT
led PRG
ACTV EXT
GND
INHAB/DISABLE
OUTPUT 12V 0.5A
MODULO RELE
BUS 2
REF. 3247
MADE IN SPAIN
GND
relay ON
+12V
NC
NO
C
RELAY MODUL
BUS 2
PRG
10xsec
sec
1 2
ON
3
1 2
ON
3
DSW1
TEST
CONFIG
DSW2
To register the addresses for all valid devices on the relay, follow the steps below:
Press the BUS2 relay’s PRG button.
The red LED lights up and flashes
to indicate that it is in programming
mode.
PRG
Led
* Operating Modes. DSW1
1)
2)
3)
Repeat steps 1 and 2 to register all the addresses (with activation authorisation) on the relay.
- The BUS2 relay exits programming mode once an address has been programmed or once 65 seconds have elapsed
without an address having been entered.
- In programming mode, the relay does not respond to activation commands.
- To delete the list of programmed addresses when outside programming mode, press and hold the PRG button for 2
seconds (the LED flashes 3 times to indicate that the records have been deleted).
Led
3.-
Exit programming
mode by pressing PRG.
The LED will switch off.