Fermax LOFT BUS2 Technical Manual Download Page 15

 

Page 15

B

B

B

B

BUS2

US2

US2

US2

US2

B

B

B

B

BUS2

US2

US2

US2

US2

Code 97462I-1   V07_09

2 1

3

4

8

5

6

7

11

9

10

1312

16 14

15

MIC

NC NO C

-

BS

BUS-2

EXIT

EXIT

B B

+12

S

JP3

JP2

PACK EXTENSION

CN1

CN2

LEDS ON

SLAVE

MASTER

LEDS OFF

TARJETERO

CARD HOLDER

CN4

CN3

AUDIO

BUS-2 VERSTÄRKER

AMPLIFICATEUR BUS-2

BUS-2 AMPLIFIER

AMPLIFICADOR BUS-2

PROG

TEST

C

NO

NC

STATUS LEDS

LEDS ESTADO

VERSION :

LANGUAGE

IDIOMA

10

PAN & TILT

D

C

B

A

JP3

JP2

CN4

CN3

SW1

CN2

MIC

JP3

JP2

ARRIBA

UP

ARRIBA

UP

ARRIBA

UP

ARRIBA

UP

REF.2441

MODULO EXTENSION 16 LLAMADAS

16 CALL EXTENSION PACK

2

1

4

3

6

5

8

7

SIGUIENTE/NEXT

ANTERIOR/PREVIOUS

CN1

One of the advantages offered by the BUS2 system is that no call wires are used.  This is possible because the call is
made through the transmission of a digital code generated by the amplifier in the outdoor entry panel when a specific
call button is pressed.

This code is sent via the 2-wire bus to all terminals in the apartment (monitors/telephones). Only the terminal which was
previously programmed with said code will recognise it and generate a call tone.

Obviously, after setting up the system, it will be necessary to programme each one of the monitors or phones with its
corresponding call code. This is easy to do as displayed in the sections corresponding to each monitor and telephone.

In order to generate the specific code for each call on City button panels, 

call extension  modules 

 are used (one for

every 16 buttons). This module translates the activation of each button on to panel into a call code. (See connection
diagrams for the call extension module).

The City panels with 1 to 3 buttons do not require the installation of a call extension module (see panel pre-cabling
diagrams).

If a larger number of buttons need to be covered, two or more modules can be used, up to a maximum of 199
apartments allowed by to BUS2 system.

Call extension module connection on City BUS2 panels

CITY BUS2 video panel

* Call extension module, ref. 2441

Call code generated by
pressing the call button

Call code assignation carried out by the call extension module can be modified by using the 

‘Mapping’

 function

available in the BUS2 amplifier. See section ‘Advanced programming - mapping’).

16 EXTENSION CALL PACK

1

REF.2441

4

3

2

7

6

5

10

9

8

12

11

15

14

1316

PACK EXTENSION 16 LLAMADAS

SIGUIENTE/NEXT

ANTERIOR/PREVIOUS

LLAMADAS/CALLS

16 EXTENSION CALL PACK

1

REF.2441

4

3

2

7

6

5

10

9

8

12

11

15

14

1316

PACK EXTENSION 16 LLAMADAS

SIGUIENTE/NEXT

ANTERIOR/PREVIOUS

LLAMADAS/CALLS

Buttons

1 to no. 6

Buttons

no. 17 to 32

16 15 14 13   12 11 10 9   8 7 6 5           4 3 2 1

32 31 30 29 28 27 26 25 24 23 22 21 20 1 9 18 17

To BUS2 amplifier

or next extension

module

SIGUIENTE/NEXT

B

AM

A

CN1

1

2

3

4

5

6

7

8

Summary of Contents for LOFT BUS2

Page 1: ...SISTEMA BUS2 Secci n I Descripci n del sistema BUS2 LIBRO TECNICO TECHNICAL MANUAL BUS2 SYSTEM Section I BUS2 System Description...

Page 2: ...462I 1 Section II BUS2 installation diagrams Code 97462I 2 BUS2 Technical Manual Section I Code 97462I 1 V07_09 This technical document of an informative nature is published by FERMAX ELECTRONICA S A...

Page 3: ...Button module interconnection 17 DIRECT BUS2 panels 18 DIGITAL BUS2 panels 20 Panels with 4 N amplifier and BUS2 adapter 22 BUS2 adapter 23 BUS2 system reception 24 MDS BUS2 decoder 27 BUS2 SYSTEM BAS...

Page 4: ...Page4 Code 97462I 1 V07_09 B B B B BUS2 US2 US2 US2 US2 B B B B BUS2 US2 US2 US2 US2...

Page 5: ...nstall a desktop guard unit which allows communication between residence guard unit residence entry panel and entry panel guard unit Added value functions BUS relay The BUS2 system offers the possibil...

Page 6: ...DE IN SPAIN PROX NEXT DISTRIB B B B B B B PREV DISTRIB B B BUS 2 OUTPUT BUS 2 INPUT FAULT FAULT ON ON DERIVACION SPLIT 1 2 SPLIT DERIVACION JP1 NO TERM JP1 TERM REF 3248 MADE IN SPAIN B B B B B B FAUL...

Page 7: ...ch the call is made and the call code generated depends on the type of entry panel Keypad panels direct The call to the apartment is made by introducing the address allocated to each apartment termina...

Page 8: ...on available on all video terminals please consult the section apartment terminals During communication the door can be opened by pressing the corresponding button on the apartment terminal End of com...

Page 9: ...d be configured as the main panel default configuration 3 Programme apartment terminals This involves assigning each apartment terminal with a call code button to identify and distinguish it from the...

Page 10: ...EM HIGH RESOLUTION CCD CAMERA PAN TILT 1 2 3 4 5 6 7 8 9 A 0 B 9 8 7 0 6 5 4 A 3 2 1 B 9 8 7 0 6 5 4 A 3 2 1 Note The panels are equipped with a card holder or space reserved for the BUS2 adapter Guid...

Page 11: ...nthesiser module can be replaced by other versions which include other languages Valencian Catalan Portuguese Polish Dutch Russian etc For more information please consult the technical information cod...

Page 12: ...S2 verifier to be connected to check the system status or to programme the apartment terminals Volume adjustment for call monitoring and voice synthesis MIC Microphone connections microphone is locate...

Page 13: ...ting Temperature Maximum audio power in direction apartment street 24Vdc on standby active audio 10 60 C 80 mA 300 mA Maximum audio power in direction street apartment Power supply 2 W 0 15 W 10 Resto...

Page 14: ...wires This is possible because the call is made through the transmission of a digital code which is generated via call extension modules see section Call extension module This module is not necessary...

Page 15: ...ed in the sections corresponding to each monitor and telephone In order to generate the specific code for each call on City button panels call extension modules are used one for every 16 buttons This...

Page 16: ...y card reader bluetooth for access control etc Programming lock release time between 1 and 99 seconds see section Advanced Programming Door release times The panel s assembly is very easy Simply selec...

Page 17: ...ls do not require a call extension module given that the button modules generate the BUS2 call code corresponding to each apartment do not confuse the BUS call code or BUS call address with the apartm...

Page 18: ...des previously programmed using the keypad Programming the door lock release time between 1 and 99 seconds The size of the DIRECT BUS2 panels is always the same series 4 with 1 recess series 6 regardl...

Page 19: ...er carrying out the necessary tasks Once the opening code has been activated this function cannot be disabled This means that an opening code will always exist regardless of whether it is known by sys...

Page 20: ...control functions using keypad codes entered on the numerical keypad the Digital panels allow the user connect a secondary card reader module from the digital panel s display The users and their card...

Page 21: ...s the time for which the door lock release will be active once the door opening button connected to the panel is pressed or when a valid user code is entered on the key pad or using the key button or...

Page 22: ...IENTE NEXT ANTERIOR PREVIOUS LLAMADAS CALLS BUS2 adapter Ref 3242 Call extension modules ref 2441 required for panels with more than 8 buttons 1 module for every 16 extra buttons 2 Direct BUS2 panel k...

Page 23: ...MPLIFICADOR 4 N 4 N AMPLIFIER AMPLIFICATEUR 4 N 4 N VERST RKER 18 Vdc VIDEO KAMERA PAN TILT 10 VIDEO TEST MONITOR REF 2490 ALIMENTACION POWER SUPPLY CT ENCUADRE E INCLINACI N 10 TELECAMARA VIDEOPORTER...

Page 24: ...the selection of and communication between the active panel reception and the general bus thus isolating other panels reception or equipment which may be connected to the bus see section Basic Devices...

Page 25: ...ION and the panel connected to the PANEL DECODER selected via the keypad Communication residence residence residence Activate the communication channel between two residences Activation deactivation o...

Page 26: ...phones or the reception using the bell key The reception guard can transfer a call to any telephone The reception guard can connect two telephones NIGHT MODE The Central Reception does not respond to...

Page 27: ...n 3 residence direction 2 3 PGM Programming button Puts decoder in programming mode 1 CN1 BUS2 system bus connection B B Data BUS2 audio and video Ct Video activation distributor 0v on standby 10 Vdc...

Page 28: ...0000 if the residence terminals are programmed from the BUS2 panel FFFF if the residence terminals are programmed from the reception MDS panel press the A key to introduce the letter F Audio 4 Telepho...

Page 29: ...EV DISTRIB B B BUS 2 OUTPUT BUS 2 INPUT FAULT ON ON DERIVACION SPLIT 2 DERIVACION B B ON FAULT ON ON FAULT FAULT B B ON FAULT DERIVACION SPLIT 4 SPLIT 1 SPLIT 3 DERIVACION NO TERM JP1 TERM JP1 BUS2 po...

Page 30: ...1 MADE IN SPAIN REF 3246 CAMBIADOR DE PLACAS BUS 2 BUS 2 PANEL SWITCHER AUX PLACA 2 PANEL 2 PANEL 1 PLACA 1 ON ON FAULT FAULT BUS 2 OUTPUT B B B B B B B B 2 PRW BUS PRW BUS PREV BUS 4820 2 2 100 240V...

Page 31: ...of fault in the bus connected to the input bus short circuit fault in connected device etc The branch shunts can be interconnected to increase the number of branches 3 Backbone 2 Backbone 1 REF 3248...

Page 32: ...f network distributors without repeater 32 with 2 outputs or 16 with 4 outputs BUS2 distributor BASIC with 2 or 4 outputs ref 3250 ref 3251 At every distributor output only the following can be connec...

Page 33: ...SPAIN PROX NEXT DISTRIB B B B B B B PREV DISTRIB B B BUS 2 OUTPUT BUS 2 INPUT FAULT ON ON DERIVACION SPLIT 2 DERIVACION B B ON FAULT ON ON FAULT FAULT B B ON FAULT DERIVACION SPLIT 4 SPLIT 1 SPLIT 3 D...

Page 34: ...ation DSW2 COMMAND Configuration of control mode control commands external activation See section BUS2 relay configuration 6 PRG Programming button Led Relay ON Relay indicator LED in programming mode...

Page 35: ...BUS 2 DISTRIBUTOR DISTRIBUIDOR BUS 2 REF 3240 MADE IN SPAIN PROX NEXT DISTRIB B B B B B B PREV DISTRIB B B BUS 2 OUTPUT BUS 2 INPUT FAULT FAULT ON ON DERIVACION SPLIT 1 2 SPLIT DERIVACION JP1 F2 F1 F2...

Page 36: ...ia the telephone monitor or panel Only one command can be selected COMMAND 1 Function to be carried out by the corresponding device Call to reception Auto start F1 activation F2 activation Door lock r...

Page 37: ...from panel mode when a call is made from the entry panel only the BUS2 relay is activated ALL PRG ON ALL Any system device that sends a valid command in accordance with that programmed on the DWS2 act...

Page 38: ...PUT BUS 2 INPUT FAULT FAULT ON ON DERIVACION SPLIT 1 2 SPLIT DERIVACION JP1 F2 F1 F2 F1 The BUS2 Repeater amplifies the BUS2 signal and as a result increases the distance covered by the system and the...

Page 39: ...IN 6 with LED indicators Requires adapter ref 3243 Adapter module Ref 3243 the adapter module is necessary when source ref 4840 is installed this power supply cannot be connected directly to the BUS a...

Page 40: ...o desconectar el primario durante un minuto aproximadamente PROTECTED BY ELECTRONIC FUSE After any short circuit disconnect the primary power supply for one minute approximately ON OVERLOAD 4840 PROT...

Page 41: ...ERO CARD HOLDER CN4 CN3 AUDIO BUS 2 VERST RKER AMPLIFICATEUR BUS 2 BUS 2 AMPLIFIER AMPLIFICADOR BUS 2 PROG TEST C NO NC STATUS LEDS LEDS ESTADO VERSION LANGUAGE IDIOMA 10 PAN TILT D C B A JP3 JP2 CN4...

Page 42: ...ms mixed monitor and telephone systems or as additional equipment in monitor systems Door lock release call reception button When conversing with the outdoor entry panel press to activate the door loc...

Page 43: ...screen colour TFT Image adjustments colour shine and contrast through controls ON OFF switch with three positions off on medium volume on low volume 2 selectable call tones Surface COMMUNICATION Telep...

Page 44: ...put Maximum current per button F1 F2 50mAat 12Vdc Termination jumpers Connectors with a single switch When there is only one terminal per distributor output turn the JP2 switch to the position NO TERM...

Page 45: ...EF 3240 MADE IN SPAIN PROX NEXT DISTRIB PREV DISTRIB BUS 2 OUTPUT BUS 2 INPUT FAULT FAULT ON ON DERIVACION SPLIT 1 2 SPLIT DERIVACION JP1 B B B B B B B B B BUS 2 DISTRIBUTOR DISTRIBUIDOR BUS 2 REF 324...

Page 46: ...er terminal programming setup Once this time has passed the terminal will exit programming mode i The Loft Compact and iLoft monitors have an additional function which enables monitor programming from...

Page 47: ...MA LANGUAGE AUDIO JP1 JP2 JP3 C 12VDC 1 MASTER SLAVE 2 DRY SECO TERM NOTERM C NC NO EXIT B B NC NO C BS PACK EXTENSION BUS 2 VERST RKER AMPLIFICATEUR BUS 2 BUS 2 AMPLIFIER AMPLIFICADOR BUS 2 COD 99914...

Page 48: ...tter B indicating that the final address must be entered Press the keys and to select the final address Press the key to confirm The verifier automatically verifies all the addresses from A to B inclu...

Page 49: ...SPY mode the verifier receives any data circulating through the BUS2 or any user commands making a call opening a door etc and shows it on the display in the following manner Three letters of each co...

Page 50: ...all button associated with this monitor residence on the entry panel The call code previously programmed on that monitor will be assigned to the button it will be stored on the amplifier Repeat step 3...

Page 51: ...or each second to be programmed from 1 to 99 seconds To programme the lock release time from the exit button while in time programming mode having finished programming the lock release time from the r...

Page 52: ...www fermax com fermax fermax com Audio and Video Door Entry Systems...

Reviews: