47
Multi Boring Machine
FD 21 professional
10.4 Faults, causes and repairs
Fault
Cause
Repair
Machine does not start
(Spindle does not turn)
Power supply
Main switch at setting „0“
Emergency stop switch engaged
Check the power supply
Check switch position
EMERGENCY STOP button: release
Boring head doesn’t proceed
(Spindle turn)
Compressed Air not present
Air supply pressure too low
Check pressurized supply
Check display pressure
Burn marks from drilling
Incorrect boring direction
Check motor direction
Check right left drill mount
Workpiece slipping
Check pneumatic arm clamp
Hold down doesn’t clamp
workpiece
Vertical adjustment of clamp
Check height of clamp
Compressed Air not present
Air supply pressure too low
Check pressurized supply
Check display pressure
Boring head doesn’t pivot
completely
Head still clamped
Check hand clamp levers
Compressed Air not present
Air supply pressure too low
Check pressurized supply
Check display pressure
Boring head doesn’t pivot
completely
(until the stop is reached)
Air supply pressure too low
Check display pressure
Tilt stop 45º Position
Tilt Stop 45°: release
Incorrect boring
Incorrect depth
Check depth stop screw
Faults