background image

(beep) is heard (after approximately 1 second). If you release 

trigger 16 at that time, the cutting head remains closed until 

the operator presses again the trigger 16. This option can be 

disabled by pressing the joystick "command: PUSH". 

""NON PROGRESSIVE MODE" MENU (FELCO 801 AND 

FELCO 820 ONLY) 

R

 

E

 

G

   

O

 

N

 

PUSH 

R

 

E

 

G

   

O

 

F

 

F

 

 

REG ON = POWERPACK FELCO 880 is factory set to the 

option of operating the blade 17  in progressive mode 

(Trigger 16 activating proportionally blade 17). However, it is 

possible to work in non-progressive mode, same as with 

pneumatic pruning shears by disabling this option via the 

joystick (PUSH command). 

CAUTION

This non progressive mode IS ACTIVE only if the tool is 

activated. Once the tool is turned off, the mode returns 

automatically to progressive. 

TROUBLESHOOTING 

"DIAGNOSTIC" MENU (FELCO 801, FELCO 820, 800 OR 

810) 

V

 

3

 

.

 

0

 

Allows you to enter the menu of diagnostics and 

troubleshooting. You can access this submenu by activating 

the joystick using "PUSH" and you can exit the menu using 

any of the functions of the joystick. The diagnostics of the 

tool and the battery(ies) are performed automatically in 

sequence. Each diagnostic procedure is executed in a loop 

until the user touches the joystick in any way. 

CAUTION 

To run complete diagnostics, a FELCO electro portable tool 

must  be plugged. The diagnostics made in this way must 

always be validated by an authorized dealer, who has 

privileged access to the online FELCO advanced diagnostics 

platform. 

BATTERY(IES) TEST 

PUSH 

B

 

A

 

T

 

1

 

O

 

K

 



B

 

A

 

T

 

1

 

K

 

O

 

AUTO 

B

 

A

 

T

 

2

 

O

 

K

 



B

 

A

 

T

 

2

 

K

 

O

 

 

This test verifies whether the battery 09 is working properly, 

or not. If everything works correctly, the status will be: OK. 

CAUTION

If only one battery 09  is connected, the test of the other 

battery 09 will have the status: KO. 

If a battery 09 is in "storage" mode and is connected to the 

control housing 04, the battery 09  status will be: KO. To 

remedy this, refer to chapter "INITIAL USE". 

POWER LINE TEST 

P

 

O

 

W

 

E

 

R

 

L

 

I

 

N

 

E

 

O

 



P

 

O

 

W

 

E

 

R

 

L

 

I

 

N

 

E

 

K

 

 

This test allows the verification of the power at motor level, 

connection level and power cord 02  level (broken power 

cord, or general problems of the power cord). If everything 

works correctly, the status will be: POWER LINE OK. 

TRIGGER LINE TEST 

T

 

R

 

I

 

G

 

G

 

E

 

R

   

L

 

I

 

N

 

E

     

O

 



T

 

R

 

I

 

G

 

G

 

E

 

R

   

L

 

I

 

N

 

E

     

K

 

 

This test allows the verification of the trigger 16 at the level of 

trigger circuit, connection level and power cord 02  level 

(broken power cord, or general problems of the power cord). 

If everything works correctly, the status of this test will be: 

TRIGGER LINE OK. 

CONTROL HOUSING TEST 

M

 

A

 

I

 

N

   

D

 

R

 

I

 

V

 

E

 

O

 



M

 

A

 

I

 

N

   

D

 

R

 

I

 

V

 

E

 

K

 

 

A self-test of the control housing 04 is performed. This allows 

the detection of certain errors. If everything works correctly, 

the status of this test will be: MAIN DRIVE OK. 

ALARMS DURING OPERATION 

During operation of the tool, it may stop. This stop may be 

due to a technical problem and if this is the case, it is 

necessary to visit your authorized dealer. Only the alarms 

described below do not require direct intervention: 

TEMPERATURE PROBLEM 

°

 

C

 

!

 

°

 

C

 

!

 

°

 

C

 

!

 

2 Sec. 

B

 

1

 

-

 

B

 

2

 

:

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

 

-

This alarm occurs if any of the following components 

becomes too hot: Battery 09, control housing 04, or motor. 

The power output is automatically reduced until the 

temperature of these components drops back to the correct 

values. 

AUDIBLE NOTIFICATIONS

 

The user is helped by sound signals emitted by the control 

housing 04 of POWERPACK FELCO 880: 

www.kipogeorgiki.gr

www.kipogeorgiki.gr

12

Τηλ

. 210 5573739

Summary of Contents for POWERPACK 880

Page 1: ...www felco com User guide pg 7 Please read carefully before use 15 EL EN www kipogeorgiki gr...

Page 2: ...2 www kipogeorgiki gr www kipogeorgiki gr 2 210 5573739...

Page 3: ...3 04 02 03 10 09 01 ON OFF 07 06 05 08 16 15 17 18 14 11 13 12 www kipogeorgiki gr www kipogeorgiki gr 3 210 5573739...

Page 4: ...mm 20 25 mm 25 30 mm 30 35 mm 35 45 mm 0 0 2 in 0 2 0 39 in 0 39 0 59 in 0 59 0 79 in 0 79 0 98 in 0 98 1 18 in 1 18 1 38 in 1 38 1 77 in 800 800G 801 801G 810 820 800 800F 801 800F 800M 801 800M B ww...

Page 5: ...5 C D E 09 09 09 09 10 PGUP PGND PUSH DECR INCR Patented Japan no JP5153930 other countries pending www kipogeorgiki gr www kipogeorgiki gr 5 210 5573739...

Page 6: ...0 O N PUSH f 1 2 6 0 O N PUSH g 1 2 7 0 O N PUSH h 1 2 O F F PUSH e PGND PGUP i C L I C K C L I C K O N PUSH j C L I C K C L I C K O F F PUSH i PGND PGUP k R E G O N PUSH l R E G O F F PUSH k PGND PG...

Page 7: ...nual may be reproduced without the written permission of FELCO SA The technical features and illustrations in this manual are provided solely for guidance and are not binding in any way Company FELCO...

Page 8: ...50 Recharge it prior to storage in case the value is less than 50 To check the charging status of the battery 09 connect the battery 09 to the control housing 04 set switch 07 to ON and visualize the...

Page 9: ...TE HOUSING NOTES In order to save the energy fed by battery 09 and to also ensure maximum autonomy for the pruning shear 15 consider using option semi opening which is adjustable to 50 60 or 70 Refer...

Page 10: ...esponsibility in case of connection of a battery other than an original FELCO SA battery Any injury or damage caused by the use of a battery that is not an original FELCO SA battery is the responsibil...

Page 11: ...ts classifications are determined on the basis of the averages and these values should be considered as an indication If you press the joystick for 2 seconds PUSH command the 3 counters of this screen...

Page 12: ...orrectly the status will be OK CAUTION If only one battery 09 is connected the test of the other battery 09 will have the status KO If a battery 09 is in storage mode and is connected to the control h...

Page 13: ...A cannot exceed the limits de ned above and covers to a limited extent repair or replacement as chosen by FELCO SA of parts recognized to be defective and when applicable the labour required to perfor...

Page 14: ...e following standards Battery T V marking According to standards IEC 62133 UL 1642 UL 2054 CE EMC marking According to standards EN55014 1 and EN55014 2 PSE According to standards DENAN ordinance Arti...

Page 15: ...5 Wh 10 11 100 VAC 240 VAC 50 60 Hz 42 VDC 2 A 12 13 14 POWERPACK FELCO 880 POWERPACK FELCO 880 POWERPACK FELCO SA FELCO SA POWERPACK FELCO 880 FELCO A 4 FELCO SA FELCO SA 11 09 11 60 C 1 5 11 09 11...

Page 16: ...09 UN 3481 9 II 967 07 06 OFF 09 04 02 04 POWERPACK FELCO 880 07 06 OFF 09 09 FELCO SA FELCO SA POWERPACK FELCO 880 FELCO A 4 POWERPACK FELCO 880 09 50 50 09 09 04 07 ON 08 06 5 09 50 09 11 09 FELCO 8...

Page 17: ...7 9 oz 545 g 19 2 oz POWERPACK 1 2 365 g 83 4 oz POWERPACK 880 14 15 09 09 09 11 4 1 09 11 2 13 11 3 11 4 12 11 5 09 12 6 11 7 09 11 8 07 OFF 9 09 04 10 02 15 03 C 5 1 2 10 3 4 5 6 7 8 9 15 07 06 OFF...

Page 18: ...ACK FELCO 880 D 5 04 09 09 08 B 1 B 2 1 2 12 11 09 2 12 11 09 04 15 07 08 06 04 B 1 B 2 04 B 1 B 2 2 04 B 1 B 2 3 13 09 11 09 11 09 09 14 50 09 11 FELCO 880 POWERPACK 11 09 POWERPACK FELCO 880 11 09 1...

Page 19: ...C 1 5 09 07 OFF POWERPACK FELCO 880 40 C 09 12 07 USB 04 USB 05 A IP67 walkman 07 laptop touch pad 06 09 06 E 5 PGUP INCR PUSH DECR PGND 06 FELCO 801 FELCO 820 07 06 0 0 X X X X X X PUSH 06 FELCO 800...

Page 20: ...FELCO 801 820 800 810 PUSH 2 RESET XX XXL 2 PUSH FELCO 801 FELCO 820 POWERPACK FELCO 880 2 16 16 2 4 50 60 70 1 2 5 0 O N 50 PUSH 1 2 6 0 O N PUSH 17 50 60 60 PUSH 1 2 7 0 O N PUSH 17 60 70 70 PUSH P...

Page 21: ...H FELCO online FELCO PUSH B A T 1 O K B A T 1 K O AUTO B A T 2 O K B A T 2 K O 09 OK 09 09 KO 09 04 09 KO P OWE R L I N E O K P OWE R L I N E K O 02 POWER LINE OK T R I G G E R L I N E O K T R I G G E...

Page 22: ...800 FELCO 810 07 10 POWERPACK FELCO 880 07 5 20 POWERPACK 07 OFF ON 09 POWERPACK FELCO 880 09 24 FELCO SA 2 18 POWERPACK FELCO 880 FELCO SA FELCO SA FELCO SA FELCO SA FELCO SA FELCO SA FELCO SA FELCO...

Page 23: ...EC 62133 UL 1642 UL 2054 CE EN55014 1 EN55014 2 PSE DENAN 1 9 C tick AS NZS CISPR 14 CE KC RoHs REACH 53SVHC T V GS CE_LVD CB IEC EN 61558 1 IEC EN 61558 NRTL CNRTL UL 1310 CAN CSA C22 2 No223 M91 CE...

Page 24: ...SET PGND PGUP c 4 2 S 3 7 M 2 1 L PUSH 2 sec RESET PGND PGUP d X X L PUSH 2 sec RESET PGND PGUP m V 3 0 3 INCR DECR Please refer to TROUBLESHOOTING PGND PGUP a FELCO 880 FELCO 800 FELCO 880 FELCO 810...

Page 25: ...SA CH 2206 Les Geneveys sur Coffrane T 41 328 581 466 F 41 328 571 930 info felco com www felco com or P O Box 1352 DE 71688 Freiberg T 49 7141 685 75 75 F 49 7141 685 75 85 www kipogeorgiki gr www k...

Reviews: