TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 74 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
To prevent unintentional movement of the door, only adjust the limit switches when the
emergency stop is activated or the controller is switched off!
12. The door may now be operated in automatic mode.
9.3
… with light curtain TST LGB
Activating the TST LGB application
The application automatically sets several of the necessary function dependent parameters.
1.
Set application parameter A.480
to "1".
2.
Automatic range query:
Set the real light curtain distance per parameter P.44A in
steps of 0.5m.
The range must be set to correspond to the door width
Open the door completely!
If the light curtain is covered, the adjacent error
message will appear and the teach-in of all end
positions must be restarted.
Zur Aufpos.
à
Hindernis T75
3.
Open CALIBRATE mode by briefly pressing the
STOP key.
! Synchron. !
I615 LL angef.
4.
Open the door completely by pressing the
OPEN-
key.
Zur Aufpos.
à
xxx Übern. mit
5.
Save by pressing the
STOP-key for approx. 3
seconds.
Zur Aufpos.
à
Folie STOP
If the door moves in the incorrect direction: incorrect
motor rotary field, turn off controller and reverse the
2 motor connections.
Zur Aufpos.
à
0 Übernahme mit
Zur Aufpos.
à
Folie STOP
Light line alignment is being requested.
LGx Qual. Test
The detection range of the light curtain must be free,
otherwise the correction movement will be aborted
and the synchronization of the light curtain will be
restarted.
6.
Start automatic teach-in of
CLOSE-position by
pressing the CLOSE-key.
! Synchron. !
0 Start mit