TST
Assembly instructions
FUF2 / FU3F-A/-C/-F
FEIG ELECTRONIC GmbH
Page 101 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
13 General messages
7-
Segm ent +
Klartext/Statusm eldungen während
Eichung/Sy nc hronisation @
0\m od_1528354701138_6.docx
@ e
General messages
7-Segment display
Real text display
Description
FUF
FUF self test
Power Up and self test
→
Initial
display after power up
àUF@
Door closes.
Closing active
@AUF
Door opens.
Opening active
'Au'
Automatic
Automatic
→
indicates change
from "Manual" to "Automatic"
status
EICH
Calibration Start with Æ
CALI:
→
calibration setting the limit
positions in deadman travel mode
(for absolute encoder )
→
Start
procedure using STOP key
_Eu_
--
Lower limit position
Eu
Locked in close position
Lower limit position locked
→
opening not possible (e.g. airlock)
-
Eo
-
--
Upper limit position
Eo
Locked in open position
Upper limit position locked
→
closing not possible (e.g. Safety
edge)
-E1-
--
Middle limit position E1
(intermediate stop position)
E1
Locked in middle position
Middle limit position locked
→
closing not possible
'Hc'
Semi-automatic
Semi-automatic
→
indicates
change from "Manual" to "Semi-
automatic"
'Hd'
Dead man mode
Manual
→
Deadman mode
NA
Emergency stop
E-STOP
→
Movement not
possible, hardware safety chain
interrupted
HdSA:
Emergency travel
Emegency-travel
→
Deadman
travel without regard for safeties,
etc.
ParA
Parametrization
Parametrization
FAIL
Fault
Fault
→
only deadman travel is
possible, automatic opening may
also be possible
STOP
STOP - Keypad
Stop
/ Reset-Modus
→
wait for
next incoming command
SYNC:
! Synchronised !
Synchronization (incremental
encoder / limit switch
→
Pos.unknown)