TST
Assembly instructions
FUF2 / FU3F -A/-C/-F
FEIG ELECTRONIC GmbH
page 100 of 114
TST_FUxF-A-C-F_Montageanleitung_EN_15
No.
Description
I.947
The Paramterfile can not be loaded because it`s forbidden
I.948
The Paramterfile can not be loaded because the file is incompatible
I.949
The Paramterfile can not be loaded because there is min. one not writeable parameter included
I.94A
The Paramterfile can not be loaded because the content is invalid
I.94F
The Paramterfile can not be loaded because of an unknown problem
I.A00
There is a new or unconfigured device on the CAN or RS485 bus.
I.A01
Poor CAN bus quality during the teach-in process:
•bad CAN BUS wiring
•no ferrite cores on the motor cable
•Incorrect CAN bus termination (missing or wrongly placed termination resistors)
•Too long CAN bus lines (>180m)
•faults on the CAN line when the door operator is moving
possible improvement:
• Ferrite core around the CAN cabling within the control unit
I.A13
The customer coding of the VEK MNST was successfully completed.
I.A63
The customer coding of the MWD BPC Sensor 1 was successfully completed.
I.A73
The customer coding of the MWD BPC Sensor 2 was successfully completed.
I.A83
The customer coding of the MWD BPC Sensor 3 was successfully completed.
I.A93
The customer coding of the MWD BPC Sensor 4 was successfully completed.