3.2.4. [0x43] Auto-Answer-Mode: data block definition
This command defines the data block which should be read Auto-Answer-Mode.
Host
→
Reader:
1
2
3
4
5
6
6
COM-Adr
0x43
AA-DB-A
AA-DB-def.
CSUM
Host
←
Reader
1
2
3
4
5
5
COM-Adr
0x43
status
1
CSUM
AA-DB-A:
This parameter defines the starting address of the data block
(max. value depends on
transponder)
, from which on the data defined by AA-DB-Def shall be read from the
transponder.
AA-DB-Def:
Bit:
7
6
5
4
3
2
1
0
Function:
-
-
-
-
-
DB-N
DB-N: (0...4):
Number of data blocks that shall be read from the transponder in auto-answer mode
started from address AA-DB-A on.
1