OBID
®
System-Manual
ID RW40.30-USB
FEIG ELECTRONIC GmbH
Page 21 of 57
H80701-2e-ID-B.doc
3.2. Configuration of Auto-Answer-Mode
3.2.1. [0x40] Auto-Answer-Mode
The protocol block and the operation mode of the Auto-Answer-Mode can be configured via the auto-
answer mode (see:
2.3. Auto-Answer-Mode
).
Host
→
Reader:
1
2
3
4
5
5
COM-Adr
0x40
AA_MODE
CSUM
Host
←
Reader
1
2
3
4
5
5
COM-Adr
0x40
status
1
CSUM
AA_MODE:
Bit:
7
6
5
4
3
2
1
0
Function:
-
EXCL_S
NR
BCD_SN
R
CYCL
-
DAT
ID_NO
S_NO
If bit 0..2 is not set, the Auto-Answer-Mode remains switched off. The contents of the protocol
block is defined by the bits 0..2, while bit 4 determines the way of operation of the Auto-
Answer-Mode.
S_NO.:
Setting of this bit activates the output of the Serial-No.
0
:
Output of the Serial-Number inactive
1
:
Output of the Serial-Number active
ID_NO.:
Setting of this bit activates the output of the ID-Number if there is an valid ID-Number
on the Transponder.
0
:
Output of the ID-Number inactive
1
:
Output of the ID-Number active
DAT.:
Setting of this bit activates the output of a specified data field (see:
3.2.4. [0x43] Auto-
Answer-Mode: data block definition
)
0
:
Output of a data field inactive
1
:
Output of a data field active
1
see ANNEX C: Index of status bytes