8.2.2. [0xA1] Set Log
This command starts the recording of the temperature of the KSW - TempSens.
REQUEST-DATA
5
6
(7 - 14)
8 (15)
9 (16)
10-11 (17-18)
0xA1
MODE
UID
Logflags
Logpointer
Logperiode
©
12-13 (19-20)
14-15 (21-22)
ª
LogLimitLo
LogLimitHi
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
-
-
-
-
-
ADR
ADR:
ADR
b000
non-addressed
b001
addressed
b010
selected
ISO-ERROR:
(only ISO transponders)
ISO error code of transponder response. This byte is only available if STATUS = 0x95.
UID:
Read-only serial no. of the transponder. The UID is required only in the addressed mode.
Logflags:
The type of measurement.
Logpointer:
Pointer of the next measurement value.
Logperiode:
Range of the measure
.
.
LogLimitLo:
Lower limit for measurement value
LogLimitHi:
Higher limit for measurement value