3.7. CFG6: Scan-Mode1
The parameters of the CFG6 configuration block contain Scan-Mode settings. To enable Scan-Mode
the SCAN-MODE bit in the configuration block CFG1 (
3.2. CFG1: Interface
) must be set.
Byte
0
1
2
3
4
5
6
Contents
SCANNER-
MODE
0x00
0x00
SCAN-DATA
0x00
0x00
SCAN-LOCK-
TIME
Default
MR100
0x02
0x01
0x00
Default
PRH100
0x80
0x01
0x00
Byte
7
8
9
10
11
12
13
Contents
SCAN-LOCK-
TIME
0x00
0x00
0x00
DB-ADR
D-LGT
D-START
Default
MR100
0x0A
1 sec.
0x00
0x04
0x00
USB
Version
0x05
Default
PRH100
0x00
0x00
0x04
0x00
SCANNER-MODE
defines the mode of the scanner.
Bit:
7
6
5
4
3
2
1
0
Function
Trigger
0
0
0
0
mode
mode:
b000:
Single Read:
(active for read duration – stops after good read)
When all Transponders in detection range has been decoded, the Reader
will stop the scan. The Reader must be triggered again to read other Trans-
ponders.
b010:
Continuos Read:
The Reader will read as much Transponders as it can decode regardless
whether it is the same or not. This mode is mainly used for demonstration
and diagnostic.
Trigger:
b0:
Trigger disabled:
The Reader scans all the time. However, this mode increase the current
consumption
b1
:
Trigger enabled: (only ID ISCPRH100)
The Reader start the scan, if the trigger is activated by the external switch.