OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 20 of 118
H01000-5e-ID-B.doc
•
Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at any
time. It answers then with the configured address.
•
Not available by the USB-Reader
BAUD
1
:
By means of this byte the baud rate of the asynchronous interface can be defined.
5:
4800 baud
6:
9600 baud
7:
19200 baud
8:
38400 baud
Note:
•
Changing of BAUD only becomes effective after writing / saving configuration block
CFG1 to EEPROM and a reset of the Reader.
•
The Reader set the baud rate to 38400 baud, if the user set an invalid baudrate.
•
Not available by the USB-Reader
TRANS-FORM
2
:
By means of this byte, several parameters for the data transmission format of the asynchro-
nous interface can be defined.
Bit:
7
6
5
4
3
2
1
0
Function:
0
0
0
0
S
D
P
P:
Kind of Parity
b00:
non Parity
b01:
even Parity
b10:
odd Parity
b11:
- do not use -
D:
Number of Data Bits
b0:
8 Data Bits
b1:
- do not use -
S:
Number of Stop Bits
b0:
1 Stop Bit
b1:
- do not use -
1
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an-
swers with STATUS = 0x11.
2
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader an-
swers with STATUS = 0x11.