8. [0xB1] Host commands for ISO15693 Custom and Proprietary Commands
This command sends custom defined commands to the Transponder.
Host
→
Reader
1
2
3
4
5...n-2
n-1,n
n
COM-ADR
[0xB1]
MFR
REQUEST-
DATA
CRC16
Host
←
Reader
1
2
3
4
5...n-2
n-1,n
n
COM-ADR
[0xB1]
STATUS
RESPONSE-
DATA
CRC16
MFR:
Manufacturer code
MFR
0xXX
0x02
STMicroelectronics
0x04
Philips
0x05
Infineon
0x07
Texas Instruments
0x08
Fujitsu
0x16
EMMicroelectronic
0x17
KSW
Note:
If the Transponder type is not known the reader uses for the read multiple block command the
block size which is defined in
3.5. CFG4: Transponder Parameters
(ISO-Blocksize)
REQUEST-DATA:
Manufacturer specific request
RESPONSE-DATA:
Manufacturer specific response
Notes:
•
Data is only transferred if STATUS = 0x00, 0x83, 0x94, 0x95.
•