OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 19 of 118
H01000-5e-ID-B.doc
3.1. CFG0: Reserved
The configuration block CFG0 is reserved for future use.
Byte
0
1
2
3
4
5
6
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
Byte
7
8
9
10
11
12
13
Contents
0x00
0x00
0x00
0x00
0x00
0x00
0x00
Default
3.2. CFG1: Interface
The parameters of the CFG1 configuration block contain the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
1
TRANS-
FORM
1
0x00
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x00
0x00
38400 Baud
e,8,1
USB-
Version
0x00
0x00
0x00
0x00
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x00
0x00
0x00
0x00
READER -
MODE
Default
0x1E
MR/PR: 0x00
PRH: 0x01
3 sec.
USB-
Version
0x0A
1 sec
COM-ADR:
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface, es-
pecially for applications with the RS485 interface.
Notes:
•
Do not configure address 255!