OBID i-scan
®
System-Manual
ID ISC.MR/PR/PRH100/101-A
FEIG ELECTRONIC GmbH
Page 113 of 118
H01000-5e-ID-B.doc
Config Block 0:
This config block activates protective functions of the Transponder.
The bits can be set only to 0 and never be reversed to 1. If block C0 is set into write protected state,
no further protective functions can be activated (hardware write protected state).
Bit
Byte
Function
Operation
Block I-Scan
Block I-Code 1
0
0
”1” = r/w, ”0” = ro
D0
5
1
"1" = r/w, ”0” = ro
D1
6
2
"1" = r/w, ”0” = ro
D2
7
3
"1" = r/w, ”0” = ro
D3
8
4
”1” = r/w, ”0” = ro
D4
9
5
"1" = r/w, ”0” = ro
D5
10
6
"1" = r/w, ”0” = ro
D6
11
7
"1" = r/w, ”0” = ro
D7
12
8
1
"1" = r/w, ”0” = ro
D8
13
9
"1" = r/w, ”0” = ro
D9
14
10
”1” = r/w, ”0” = ro
D10
15
11
-
-
-
12
-
-
-
13
-
-
-
14
-
-
-
15
-
-
-
16-23
2
-
-
-
24
3
-
-
-
25
-
-
-
26
-
-
-
27
”1” = r/w, ”0” = ro
C2
4
28
”1” = r/w, ”0” = ro
C1
3
29
"1" = r/w, ”0” = ro
C0
2
30
”0” = ro
S-NO
1
31
”0” = ro
S-NO
0