8.1. Infineon Custom Commands
This commands supports the functions of the Infineon transponder
8.1.1. [0x10] Read
This command reads one or more data blocks. The user can decide to use the customer command or
the command in ISO-Mode ([0x23] Read Multiple Blocks).
REQUEST-DATA
5
6
(7...14)
7 / (15)
8 / (16)
0x10
MODE
UID
DB-ADR
DB-N
RESPONSE-DATA (STATUS = 0x95)
5
ISO-ERROR
RESPONSE-DATA
5
6
7
8...n
DB-N
DB-SIZE
SEC-STATUS
DB
Repeated DB-N times
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
DB-ADR:
First block number to be read. First block can be any value between 0 and 255.
DB-N:
Number of data blocks to be read from the Transponder, starting at DB-ADR.
The maximum number of DB-N is 16 (128 bytes)
ISO-ERROR:
(only ISO15693 Transponders)
ISO15693 error code of Transponder response. This byte is only available if STATUS = 0x95.
DB-SIZE:
Number of bytes of one data block(8 Bytes).
SEC-STATUS:
Block security status of followed data block. Sec-Status is not supported, this value will return
0x00.