OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 33 of 174
H90692-16e-ID-B.doc
RF-POWER
6
:
Defines the RF output power.
Bit:
7
6
5
4
3
2
1
0
Function
MUL
0
LEVEL
MUL
Selects the multiplier for LEVEL
b0
RF-POWER = LEVEL * 1W
b1
RF-POWER = LEVEL *
¼
W
LEVEL
Level of the RF output power
LEVEL
RF-POWER (MUL = b1)
1
0.25 W
2
0.50 W
3
0.75 W
4
1.00 W
...
...
39
9.75 W
40
10.0 W
41
10.25 W
Notes:
•
A monitor is continuously checking the RF hardware and if an error occurs the
Reader answers every command with the error code 0x84.
•
Changing of RF-POWER only becomes effective after writing / saving configuration
block CFG3 to EEPROM and a reset of the Reader
EAS-LEVEL:
(only
I-Code 1 Transponders I-Code SLI (ISO15693))
Defines the number of correct bits for the EAS command.
FSK-RX-CHN
1
:
(only FSK Transponders)
selects the receive antenna type.
0x00
only complementary antenna
0x01
only basic antenna
0x02
both antennas
Note:
•
If a basic antenna and a complementary antenna and FSK is used FSK-RX-CHN must
be set to 0x02.
6
A plausibility check is performed by writing this parameter to the Reader. If an error occurs the Reader answers
with STATUS = [0x11].