7.4.2.3. Fujitsu (MB89R119)
Chip ID: 2h = 00000010b (Bit 47 - 40 of UID)
Memory organization: 256 x 8 Byte = 16kBit
Number of blocks
256 (user area: 0 – 249)
Block size
4 byte
Command
Code
Function
Mode
Comment
non-
addressed
addressed
select
0x01
Inventory
√
-
-
0x02
Stay Quiet
√
-
√
-
0x22
Lock Multiple Blocks
√
√
√
-
WR-OPTION = 0 or 1
0x23
Read Multiple Blocks
√
√
√
-
DB-Size = 8
Security Status is always
0x00
0x24
Write Multiple Blocks
*
√
√
√
-
DB-Size = 8,
WR-OPTION = 0 or 1
0x25
Select
-
-
-
-
0x26
Reset to Ready
√
√
√
-
0x27
Write AFI
√
√
√
-
WR-OPTION = 0 or 1
0x28
Lock AFI
√
√
√
-
WR-OPTION = 0 or 1
0x29
Write DSFID
√
√
√
-
0x2A
Lock DSFID
√
√
√
-
0x2B
Get System Information
√
√
√
-
0x2C
Get Multiple Block Security
Status
-
-
-
-
*
The WR-OPTION will be set automatically by the FEIG Readers if the RW-OPTION parameter
in “
3.8. CFG8: General Transponder Parameters
” is set to “00: automatically set”. Up to two
blocks of data can be written for one request.
•
ASK SUB-CARRIER and Datacoding 1 of 4 must be configured in the reader (see: “
3.8.
CFG8: General Transponder Parameters
”)