7.1.5. [0x24] Write Multiple Blocks
This command writes one or more data blocks.
The supported ISO15693 Host commands depend on the different ISO15693 Transponder types,
which are described in chapter
7.4. Supported ISO15693 Host commands for ISO15693-Transponders
.
REQUEST-DATA
4
5
(6...13)
6 / (14)
7 / (15)
8 / (16)
9...n / (17...n)
0x24
MODE
UID
DB-ADR
DB-N
DB-SIZE
DB
Repeated
DB-N times
RESPONSE-DATA (STATUS = 0x03)
5
DB-ADR-E
RESPONSE-DATA (STATUS = 0x95)
5
6
ISO-ERROR
DB-ADR-E
MODE:
Bit:
7
6
5
4
3
2
1
0
Function
0
0
0
0
0
ADR
ADR:
b000
non-addressed
b001
addressed
b010
selected
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed mode.
DB-ADR:
Address of the first data block to be written to the Transponder. First block can be any value
between 0 and 255.
DB-N:
Number of data blocks to be written to the Transponder, starting at DB-ADR. The maximum
number of DB-N, depends on DB-Size. The maximum number of bytes is 128 bytes.
DB-Size
Max. DB-N
4
0x20 ->32
8
0x10 ->16
x
= 128 / x
DB-SIZE:
Number of bytes of one data block. This value depends on the specification of the
Transponder manufacturer, see chapter
7.4. Supported ISO15693 Host commands for
ISO15693-Transponders