OBID i-scan
®
System-Manual
ID ISC.LR200
FEIG ELECTRONIC GmbH
Page 87 of 174
H90692-16e-ID-B.doc
Notes:
•
This command supports all Transponders.
•
If ONT = b1 only the Serial Numbers of those Transponders are read which came into the
antenna field since the last Inventory command.
•
If ONT = b0 a RF-Reset is performed to read the Serial Numbers of all Transponders inside
the antenna field.
•
If the STATUS byte of the protocol frame has the value 0x94 more Serial Numbers can be
read out of the Reader with MORE = b1.
•
Using I-Code EPC and only under condition that min. max. Timeslots=1 (CFG13 Anticollision)
and only I-Code EPC driver is active (CFG3:RF-Interface I):
If the CRC of the EPC code is wrong the status “0x02 Data False” and the faulty serial
number will appear. Otherwise status 0x01 (no transponder in reader field) will appear.
•
If status 0x83, 0x84 or 0x85 appears the data set will be transferred nevertheless. If no
transponder was detected, no data set will be transferred.