![Feig Electronic OBID i-scan HF LRM2500 Installation Manual Download Page 67](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-hf-lrm2500/obid-i-scan-hf-lrm2500_installation-manual_3859275067.webp)
OBID
i-scan
®
HF
Installation
LRM2500
FEIG ELECTRONIC GmbH
Seite 67 von 69
M00910-8e-ID-B-ANATEL.doc
Annex A
Terminal assignment “Terminal Board”
Terminal
Acronym
Description
X1 / LR
24V DC Reader
X1 / Pin 1
+24 V DC Reader
X1 / Pin 2
GND
GND Reader
X2 / I/O
24V DC Input/Output
X2 / Pin 1
+24 V DC Output 2 (Sounder / Buzzer)
X2 / Pin 2
Output 2 Emitter (Sounder / Buzzer)
X3 / MUX
24V DC Multiplexer
X3 / Pin 1
+24 V DC Multiplexer
X3 / Pin 2
GND
GND Multiplexer
X4 / TRG
Trigger People Counter 1
X4 / Pin 1
+
Input 2, TRG Trigger People Counter
X4 / Pin 2
-
Input 2 GND Trigger People Counter
X5 / GPC-in
Connection Cable to People Counter
X5 / Pin 1
+24V DC LED2
X5 / Pin 2
+24V DC LED3
X5 / Pin 3
+24V DC LED1
X5 / Pin 4
RS485-A
X5 / Pin 5
RS485-B
X5 / Pin 6
TRG Trigger People Counter
X5 / Pin 7
+24 V DC People Counter
X5 / Pin 8
GND
GND People Counter
X6 / LED1
Connection LED / Alarm light antenna
X14 / Pin 1
+
+24V DC LEDB
X14 / Pin 2
-
GND LEDB
X11
24V DC Power Supply
X11 / Pin 1
24V
Power 24 V DC