Outputs
– 1 Optocoupler
– 1 Optocoupler
– 3 Relay ( 3 x NO)
24 V
/ 30 mA
Reader Synchronization
24 V
/ 1 A
•
Inputs
– 1 Optocoupler
– 1 Optocoppler
Max. 24 V
/ 20 mA
Reader Synchronisation
•
Interfaces
RS232
USB
Ethernet (TCP/IP)
•
Protocol Modes
FEIG ISO HOST
BRM (Data Filtering and Data Buffering)
Scan Mode (RS 232)
Notification Mode (TCP/IP)
•
Supported Transponders
ISO 15693, ISO 18000-3-A, (EM HF ISO
Chips, Fujitsu HF ISO Chips, KSW Sensor
Chips, Infineon my-d, NXP I-Code , STM ISO
Chips, TI Tag-it)
NXP I-Code 1
•
Ranges / pass-through width in gate
with multiplexer
– One tag orientation
– All tag orientations
approx. 140 / 150 cm**
approx. 110 / 120 cm***
•
Antenna connection
1 x SMA plug (50
Ω
)
•
Antenna connector cable
- Type B
RG58, 50
Ω
, approx. 8,55 m long