![Feig Electronic OBID i-scan HF LRM2500 Installation Manual Download Page 26](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-hf-lrm2500/obid-i-scan-hf-lrm2500_installation-manual_3859275026.webp)
OBID
i-scan
®
HF
Installation
LRM2500
FEIG ELECTRONIC GmbH
Seite 26 von 69
M00910-8e-ID-B-ANATEL.doc
Configuration of a Gate Antenna with Multiplexer
Connect the components as shown in Fig. 13. Almost, all cable should be mounted already.
Normally, the antenna cable from antenna Type B has to be connected to OUT2 at the multiplexer
and the 24V DC power supply to X11 of the terminal board only. Optional the cable of the signal
light of antenna Type B has to be connected to X12 LED2 (third antenna X14 LED3) of the terminal
board.
Fig. 13: Connecting the components for a gate consisting of two antennas, reader and multiplexer
Gate People Counter
ID ISC.ANT1800/700-GPC
Radar Module
ID ISC.ANT1800/700-GPC
X6
ANT1
HF- Antenna A
135 cm
X1
7,20 m
IN
OUT 2
OUT 1
LED3
3. Antenna
LED2
2. Antenna
DC Power
Supply24 V
X3
X2
Multiplexer
ID ISC.ANT.MUXM
Long Range Reader
LRM2500
Second GPC
4. Antenna (Type B)
Optional