Reader Setting for Indicator
The ISOStart software can be used to set the Reader configuration so that the output 1 X6-1/-2
opens or closes or the outputs of the People Counter closes when a Transponder is read.
Step
Action
Note
1
Start ISOStart Software
2
Select “Configuration” and
click on “Read” to read the
complete configuration.
3
Operating Mode
Select Buffered Read Mode.
4
Digital IO:
Output Idle Mode: OFF
Idle Flash Mode: 1Hz
Setting Time:
with „Setting Time“ set
time of output 1 for alarm
duration.
(10 means 1 second)
(e.g. 10 x 100ms)
Assign Output 2 to antenna
1+2. „True“ means: Output 1
and will be active if the
reader read a valid trans-
ponder.
5
Set by clicking on „Apply“.
6
Ext. IO:
Enable People Counter by
setting to “True”
Set Detect Mode to “Search
up to Busaddress 1”