Testing the Gate Antenna
After tuning the gate antenna, you can check for proper function using a reader, the ISOStart
service software and a Transponder. Here the Noise Level and performance of the gate are tested.
Checking the Noise Level
Step
Action
Note
1
Activate antenna 1 with
command: „Function Unit
Commands - Multiplexer“
Parameter:
„Channel Select“
„Cascade Level = 1“
„Output Channel of Input 1
= 1“
2
Confirm with “Send”
3
Activate “Test and
Measurement”
4
Select „Noise Level“ and
start by clicking on „Start“
5
Normal Noise Level values:
Average:
< 20mV
Difference (Max-Min):
< 20mV