![Feig Electronic OBID i-scan HF LRM2500 Installation Manual Download Page 50](http://html1.mh-extra.com/html/feig-electronic/obid-i-scan-hf-lrm2500/obid-i-scan-hf-lrm2500_installation-manual_3859275050.webp)
OBID
i-scan
®
HF
Installation
LRM2500
FEIG ELECTRONIC GmbH
Seite 50 von 69
M00910-8e-ID-B-ANATEL.doc
Configuration and Test
To activate the People Counters the following settings has to be done.
Set additional the Jumpers JP10 and J11 of Reader LRM2500 to configure the RS485 interface.
Fig. 23 (see also manual M01111-xde-ID-B , page 54 and 55). The Termination has to be activated
via software in the reader configuration.
J11
VCC
J10
500
Ω
500
Ω
RS485 +
RS485 -
Fig. 23: Jumper settings RS485 Interface
By using several People counters at gates with 3 to 6 aisles, you have to set the corresponding
bus address. The bus address could be set by the Dip-Switch at the People Counter Board. See
Fig. 24. At one reader, up to 3 People Counter (bus address 1-3) could be operated.
Fig. 24: Position of Dip Switch at People Counter Board
Table 10 Setting the bus address of the People Counter
DIP-Switch S1
bus address
1
2
3
4
1
OFF/ON
OFF
OFF
OFF
2
OFF
ON
OFF
OFF
3
OFF
OFF
ON
OFF
4
Reserved