Afterwards set the operating power, Transponder Parameters and ISO Host Mode:
Step
Action
Note
1
Select “Configuration”
2
Air Interface:
“Output -Power” = 8W
„Multiplexer Enable“
„1 Input (Single Mode)“
„No of Output Channels „
(e.g. 2)
„Antenna Active Time“
100 x 5ms
3
Set by clicking on „Apply“.
4
Transponder:
Configure the parameters as
following:
•
„Driver“ – here ISO 15693
•
„Anticollision“ – enable
•
„No of Timeslots“ –
1 timeslot
•
„Data Coding“ – 1 of 4
•
„AFI“ – Disabled
Note: National RF regulations may require different set-
tings.
0. Configure the reader in accordance with national
RF regulations
5
Set by clicking on „Apply“.
6
Operating Mode:
For antenna tuning the reader
has to be set to „Host Mode“.
7