Manual
MWD BP
FEIG ELECTRONIC GmbH
Page 37 of 97
MWD BP_Handbuch_mehrsprachig_8.doc
E N G L I S H
P.
Setting
range
Function
Description / note
Factory
setting
O
.
0 ... 3
Object tracking
A detected object can be tracked by the motion detector
even if it is moving very slowly. The sensitivity is specified
with this parameter.
0: off
1: low
2: medium
3: high
)
If this function is activated, minor movements such as,
e.g. leaves, rain or snow can cause continuous activation.
0
t
.
0 ... F
Output on delay
time
A relay activation delay time can be set for each of both
available channels.
0: 0
s
1: 0.2
s
....
F: 3.0
s
)
The respective value set is a multiple of 0.2 s.
)
The settings A to F correspond to the values 10 to 15.
0
T
.
0 ... F
Output off delay
time
A relay dropout delay time can be set for each of both
available channels.
0: 0
s
1: 0.2
s
....
F: 3.0
s
)
The respective value set is a multiple of 0.2 s.
)
The settings A to F correspond to the values 10 to 15.
2
12 List of the parameters for adjusting the relay functionality
Parameter mode must be started before setting the parameters. The relay to be parameterised is selected
according to the following table depending on the device address.
Address
1 3 5 7 9 B D
Relay 1
1 3 5 7 9 B D
Relay 2
2 4 6 8 A C E