Manual
MWD BP
FEIG ELECTRONIC GmbH
Page 40 of 97
MWD BP_Handbuch_mehrsprachig_8.doc
E N G L I S H
16 Convenience Profiles
Profile No.
1
2
3
4
5
6
7
8
9
Channel
I
II
I
II
I
II
I
II
I
II
I
II
I
II
I
II
I
II
Sensitivity
9
9
9
9
9
9
9
9
9
Direction
appr.
appr.
appr.
appr.
appr.
appr.
appr.
appr.
appr.
Human
detection
-
-
-
= 3
-
-
-
= 3
-
-
-
Vehicle
detection
-
-
-
-
= 4
-
-
-
= 4
-
-
Cross traffic
suppression
-
-
-
-
-
= 2
-
-
-
= 2
-
Slow object
tracking
-
-
-
-
-
-
= 2
-
-
-
= 2
Activation
delay
-
-
-
-
-
-
-
-
-
Detec
tion
Dropout
delay
400 ms
400 ms
400 ms
400 ms
400 ms
400 ms
400 ms
400 ms
400 ms
Assignment
(Logic)
X
X
X
X
X
X
X
X
X
Relay 1
OP/NP
OP
OP
OP
OP
OP
OP
NP
NP
NP
Assignment
(Logic)
X
X
X
X
X
X
X
X
Relay 2
OP/NP
OP
OP
OP
OP
OP
OP
NP
NP
NP
Comment
Factory
setting:
other
parameter
s such as.
e.g. the
device
address
(=1) are
also reset.
Channel 2
switched
off
Corre-
sponds to
factory
setting,
however
without
resetting
additional
parameters
such as
device
address, ...
Channel
1:
only
persons
(medium)
Channel
2:
only
vehicles
(medium)
Channel 1:
all
Channel 2:
without cross
traffic
(medium)
Channel 1:
all
Channel 2:
with
tracking
slow
objects
(medium)
As for
profile No.
4,
however
NP
As for
profile No.
5,
however
NP
As for
profile No.
6,
however
NP
OP = Open circuit current principle
NP = No-load current principle
appr. = approaching movement