Manual
MWD BP
FEIG ELECTRONIC GmbH
Page 39 of 97
MWD BP_Handbuch_mehrsprachig_8.doc
E N G L I S H
P.
Setting
range
Function
Description / note
Factory
setting
S
.
0 ... 3
Miscellaneous
Settings
The LED display and the buttons on the case can be
deactivated with this parameter.
0: buttons and display off
1: buttons activated, display off
2: only display activated
3: buttons and display on
)
Irrespective of this parameter setting, it is always
possible to operate the MWD BP using the buttons within the
first 15 minutes after switching on the power supply.
)
Buttons and display are always active during
parameterisation.
)
Starting parameterisation using the remote control is
possible at any time.
)
If the display is switched off, an activated output relay is
only shown on the display using the decimal point.
3
i
.
Display version
information
Output of the firmware version using 7-segment display:
-
Manual, each display point with
key
-
Automatic, in seconds cycle with the "i“ key
)
The software version is, e.g.
1.10b-A_240406
15 Causes of faults
The following can be the causes of faults for incorrect reactions of the motion detector:
-
moving parts in the sector
-
vibrations which are transferred to the device via the mounting bracket
-
electrical faults via the connection cable
-
electric fields (radio)
-
fluorescent or gas discharge lamps in the detection area
-
reflection of the radar rays on conductive floors or walls