Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 102 of 153
H01113-4e-ID-B.docx
3
IC reference
0: Information on IC reference field is not present
1: Information on IC reference field is present
4
MOI
0: 1 byte addressing
1: 2 byte addressing
5
VICC Command list
0: Data field of all supported commands is not present
1: Data field of all supported commands is present
6
CSI Information
0: CSI list is not present
1: CSI list is present
7
Extended Get System
Info parameter Field
0: One byte length of Info flag field
1: Two byte length of Info flag field
UID:
Read-only serial number of the Transponder. The UID is required only in the addressed
mode.
ISO-ERROR:
ISO15693 error code of Transponder response. This byte is only available if STATUS =
0x95. See:
ANNEX F: Transponder Error Codes
DSFID:
Data Storage Format Identifier of the Transponder.
UID:
The LSB (32bits) from the Read only Serial Number of the Transponder.
AFI:
Application Family Identifier. If not supported by the Transponder, this value will return
0x00.
Manufacturer Code:
Manufacturer specific code (see: