Identification
Manual
ID ISC.MR102
FEIG ELECTRONIC GmbH
Page 25 of 153
H01113-4e-ID-B.docx
4.2. CFG1: Interface
The parameters of the CFG1 configuration block contains the data communication settings.
Byte
0
1
2
3
4
5
6
Contents
COM-ADR
0x00
BAUD
2
TRANS-
FORM
1
0x00
0x00
TR-
RESPONSE-
TIME
Default
0x00
0x08
0x01
0x01
0x00
38400 Baud
e,8,1
Byte
7
8
9
10
11
12
13
Contents
TR-
RESPONSE-
TIME
0x00
0x00
Protocol
Mode
SCAN-
INTERFACE
Interface
READER -
MODE
Default
0x2C
1,5 sec.
0x00
USB:0x02
RS232:0x00
RS485: 0x01
0x80
0x00
COM-ADR:
(HostInterface.Serial.BusAddress)
Bus address of the Reader (0 .. 254) for communication via the asynchronous interface,
especially for applications with the RS485 interface.
Notes:
Do not configure address 255!
Via the COM-Adr 255 in the send protocol, the Reader is able to be addressed at
any time. It answers then with the configured address.
BAUD
1
:
(HostInterface.Serial.Baudrate)
By means of this byte the baud rate of the asynchronous interface can be defined.
0x05:
4800 baud
0x06:
9600 baud
0x07:
19200 baud
0x08:
38400 baud
0x09:
57600 baud
0x0A:
115200 baud
Note:
Changing of BAUD only becomes effective after writing / saving configuration
block CFG1 to EEPROM and a reset of the Reader.
The Reader set the baud rate to 38400 baud, if the user set an invalid baud rate.
The baud rate is used for both interface port’s (RS232 and RS484) of the ID
ISC.MR102.
2
A reasonableness check is performed by writing this parameter to the Reader. If an error occurs the Read-
er answers with STATUS = 0x11.