H01113-4e-ID-B.docx
Error Conditions (1
st
Byte):
Error
Set condition
Clear condition
RF Power
alternating LED
red/green 8Hz
False Power
No HF Power
Check antenna
connection
OFF
ON
Wrong antenna
Impedance
absolute impedance value
|Z|
<<50Ω<<|Z|
Check and tune
antenna
ON
ON
HF-short circuit
OFF
NOISE
Noise to high
Check environment,
antenna, cable
ON
ON
DC Power Error
Short circuit on antenna output
and DC < 1V
Check cable and
antenna
ON
ON
TEMP ALARM
temp
alarm level
100°C
temp < alarm level
OFF