FRIGERATION & ELECTRICAL DATA
BEFORE 01/01/2021
FCCR-4
FCCR-5
FCCR-6
Refrigerant (R-134A)
18 oz.
18 oz.
18 oz.
ALL MODELS ARE 115 VOLT, 60 HERTZ, 1 PHASE
AMPS
AMPS
AMPS
Compressor
RLA
6.1
6.1
6.1
LRA
40.0
40.0
40.0
Condenser Fan Motor
0.6
0.6
0.6
Evaporator Fan Motor
0.4
0.4
0.4
Lamp Circuit
0.94
0.94
1.0
Humidity Air Heater
1.6
1.6
1.6
Condensate Evaporator
1.6
1.6
1.6
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit
Ampacity.
BEFORE 01/01/2021
FCCR-4R
FCCR-5R
FCCR-6R
Refrigerant
R-134A
R-134A
R-134A
ALL MODELS ARE 115 VOLT, 60 HERTZ, 1 PHASE
AMPS
AMPS
AMPS
Evaporator Fan Motor
0.4
0.4
0.4
Lamp Circuit
0.94
0.94
1.0
Humidity Air Heater
1.6
1.6
1.6
Condensate Evaporator
1.6
1.6
1.6
Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit
Ampacity.