background image

17 

 

 

REPLACEMENT PARTS 
MODEL FCCR-4, FCCR-5, FCCR-6 

 
 

Part Description 

 

 

Part Number 

 

 

Refrigeration System 

 

 

FCCR-4 

FCCR-5 

FCCR-6 

 
Condensing Unit (Before 9/15/2014)  

30-19110 

30-19110 

30-19110 

   

Compressor (Before 9/15/2014) 

 

 

   

Condensing Unit (After 9/15/2014)   

30-20294 

30-20294 

30-20294 

Replacement Compressor (After 9/15/2014)  30-20350 

30-20350 

30-20350 

 

Evaporator Coil 

 

 

 

33-12247 

33-12247 

33-12248 

Expansion Valve 

 

 

 

32-19111 

32-19111 

32-19111 

Evaporator Fan Motor  

 

 

41-11628 

41-11628 

41-11628 

 

Evaporator Fan Blade  

 

 

72-32507 

72-32507 

72-32507 

 

Filter Drier 

 

 

 

 

32-11451 

32-11451 

32-11451 

Thermostat  Before 09/01/21   

 

32-12537 

32-12537 

32-12537 

Electronic Temp Control After 09/01/21 

32-19864-19  32-19864-19  32-19864-19 

Temp Probe 5’ length  

 

 

32-21046 

32-21045 

32-21046

 

Humidstat 

 

 

 

 

32-19100 

32-19100 

32-19100 

Condensate Evaporator 

 

 

40-32903 

40-32903 

40-32903 

Thermostat Knob Black 

 

 

72-12618 

72-12618 

72-12618 

 

 

Humidistat Knob White 

 

 

furnished with humidistat does not have number 

 
 

Electrical Components

 

 
Power or Light Switch 

 

 

41-11066 

41-11066 

41-11066 

Ballast  

 

 

 

 

39-12904 

39-12904 

39-12903 

Power Supply

 24V

 

 

 

 

39-20986 

39-20986 

39-20986 

Light Bulb 

 

 

 

 

42-11069 

42-11070 

42-11071 

Light led 24V 

 

 

                    42-2871-38C35   42-20871-54C35  42-20871-66C35 

Light Socket (Stationary) 

 

 

42-10834 

42-10834 

42-10834 

Light Socket (Spring Loaded)  

 

42-10833 

42-10833 

42-10833 

Air Heater, Tubular   

 

 

40-12545 

40-12545 

40-12545 

 
 
 
 
 
 

Summary of Contents for FCCR-4

Page 1: ...efrigerated Models INSTALLATION OPERATION INSTRUCTIONS KEEP THIS MANUAL FOR FUTURE REFERENCE Engineering and technical data are subject to change without notice FEDERAL INDUSTRIES 215 Federal Avenue B...

Page 2: ...TING INSTRUCTIONS 9 10 Initial Start Up 9 Chocolate Confectionary Display Conditions 9 Controls 9 Shelves 10 Light Replacement 10 Tilt Out Front Glass 10 Doors 10 Placing Product into Case 10 Refriger...

Page 3: ...nts contain technical instructions intended only for persons qualified to perform electrical work DANGER Improper or faulty hookup of electrical components in the case can result in severe injury or d...

Page 4: ...ed in the warning and safety messages DANGER Severe injury or death will occur if you ignore the message WARNING Severe injury or death can occur if you ignore the message CAUTION Minor injury or dama...

Page 5: ...o the direct rays of the sun heating ducts grills radiator or ceiling fans nor should it be located near open doors or main door entrances Also avoid locations where there are excessive air movement o...

Page 6: ...supported by two 2 pins attached to the case end Pick up the grill on either end and move it to the right to lift it off the locating pins Front Panel The flat front panel attaches to the case using s...

Page 7: ...f brackets Plug the shelf light cord in the light sockets Make certain the light cord is completely inserted into the socket or arcing may result causing damage to the plug and socket After 11 01 21 h...

Page 8: ...t be done in accordance with all applicable local regional or national electrical standards A separate circuit for each display case is recommended to prevent other appliances on the same circuit from...

Page 9: ...Set point adjust mode QUICK REFERENCE CARD ADJUSTMENT Hold 3 seconds to start system if off Hold 3 seconds to shut down system if on Hold for 3 seconds to enter set point adjust mode Hold 3 seconds f...

Page 10: ...shed with plastic safety light shields Make certain the light shields are always in place to safeguard against bulb breakage When replacing lights use direct equivalents to the original bulbs Light Re...

Page 11: ...to prevent electrical damage to the case NOTICE Shut off lights and power switches and remove all product from case Allow sufficient time for the unit to reach room temperature before proceeding with...

Page 12: ...soapy water Wipe off all soapy water with a damp cloth and allow to dry NOTE Depending on the amount of usage and spillage of foreign material some fasteners may have to be removed and parts disassemb...

Page 13: ...L Technical Support please contact Phone 800 356 4206 and choose the Tech Support Warranty Option Email Service federalind com For Warranty Compressors please contact the Parts Department Phone 800 35...

Page 14: ...and outlet slots are not blocked Be sure front glass is closed tightly and back doors are closed Check for a blocked or dirty condenser coil Check interior airflow Lack of adequate cold airflow could...

Page 15: ...n the general area of the case Any case malfunction or housekeeping problem that creates a slip fall hazard around or under a case should be corrected immediately SALE DISPOSAL Owner Responsibility If...

Page 16: ...6 1 6 Condensate Evaporator 1 6 1 6 1 6 Refer to the rating plate data attached to the rear of the case for Maximum Fuse Size and Minimum Circuit Ampacity BEFORE 01 01 2021 FCCR 4R FCCR 5R FCCR 6R Ref...

Page 17: ...Before 09 01 21 32 12537 32 12537 32 12537 Electronic Temp Control After 09 01 21 32 19864 19 32 19864 19 32 19864 19 Temp Probe 5 length 32 21046 32 21045 32 21046 Humidstat 32 19100 32 19100 32 1910...

Page 18: ...2 12604 Glass Shelf Bottom 52 12599 52 12602 52 12605 Door R H Reflective 53 12550 53 12552 53 12554 Door L H Reflective 53 12551 53 12553 53 12555 Light Shield 42 30209 42 30209 42 30209 Shelf Suppor...

Page 19: ...71 54C35 42 20871 66C35 Light Socket stationery 42 10834 42 10834 42 10834 Light Socket spring loaded 42 10833 42 10833 42 10833 Air Circulation Fan 41 11170 41 11170 41 11170 Misc Components Front Cu...

Page 20: ...20 WIRING DIAGRAM FCCR 4 FCCR 5...

Page 21: ...21 WIRING DIAGRAM FCCR 6...

Page 22: ...22 WIRING DIAGRAM FCCR 4 FCCR 5 REMOTE...

Page 23: ...23 WIRING DIAGRAM FCCR 6 REMOTE...

Page 24: ...HERTZ 1 PHASE 120 VOLTS BLK W G BLK W B B W W W W W W BJW 09 01 21 E 3351 12 FCCR LED LIGHTING MODEL COLOR CODE BLK BLACK W WHITE R RED B BLUE Y YELLOW G GREEN BRN BROWN W Y Y Y Y TOP LIGHT SHELF LIGH...

Page 25: ...G Y B G B Y G B B Y Y B B Y Y SHELF LIGHT SHELF LIGHT SHELF LIGHT R BLK LIGHT SWITCH BLK FAN SWITCH BLK W COLOR CODE BLK BLACK W WHITE R RED B BLUE Y YELLOW G GREEN BJW 01 25 13 E 1250 1 UNIT MUST BE...

Page 26: ...B B G B Y Y R Y Y Y B G B Y Y G B Y SHELF LIGHT SHELF LIGHT BRN B BRN POWER SUPPLY BLK B B G G G BLK B R R BLK B BLK RECP PLUG Y B G B Y Y G B Y SHELF LIGHT BLK B R R COLOR CODE BLK BLACK W WHITE R R...

Page 27: ...27 REV CHANGE RECORD APP D DATE ECN A ADDED R513 SES 11 1 19 3552 B ADDED DIGITAL CONTROL BJW 09 07 21 3734 C ADDED FCC CASES BJW 11 04 21 3734 REV 1...

Reviews: