6
Leveling the Case
The case must be level for proper drainage of defrost condensate to the condensate evaporator
reservoir.
The case must be level for the front glass to seal properly. The leveled case can be sealed to the floor
using a NSF Listed Sealant.
Grill Removal
There is a removable slotted panel at the rear of the case. The panel allows access to the condensing
unit, the light ballast, the condensate pan, and the field wiring connection box. Remove this panel to
make field wiring connections. See electrical information and grounding section of this manual
before wiring case.
To remove the air grill, open the rear storage door and remove the two (2) screws along the right
edge of the grill. The left end is supported by two (2) pins attached to the case end. Pick up the grill
on either end and move it to the right to lift it off the locating pins.
Front Panel
The flat front panel attaches to the case using screws and brackets that fit into pockets on the base
front. To remove the panel, slide it upward to get the mounting brackets and screws out of the
pockets.
Removal of this panel allows access to the compressor service ports.
Condensate Evaporator
This case is furnished with an electrical condensate evaporator. Plumbing connections are not
required.
The condensate evaporator is located toward the front of the machine compartment and is accessible
from the rear of the case.
Make sure that the drain line has not been dislodged during shipment and that the drain trap is
located properly over the water reservoir of the condensate evaporator pan.
DANGER: Electric shock hazard. Do not operate unit with
panels removed.