51
Configuring Informers Using Commander Software (Optional)
Setup, Program, and User Manual
Federal Signal www.fedsig.com
Fields
Description
Delay
Delays for a fixed number of seconds. Enter the desired delay
time, and then click OK. This function inserts a delay into the
function. For example: Activate a relay to turn on a strobe, delay
10 seconds, and then sound voice message alert. Enter between
2-500 seconds.
Relay Cycle
This function specifies relay timing cycle for each relay on the
Informer. To change the value, highlight the desired selection and
enter a new value.
Time values have a resolution of 0.5 seconds. A value of 10.5
specifies a time of 10 and one half seconds. All values are rounded
to the nearest half second.
Enter between 0-255 for On and Off. Enter between
0-65535 seconds for Total.
Relay On/Off
(The Informer15 and
Informer100 use
Relays 1 and 2.
I-IPSIU uses Relays
1 through 4.)
Relay #1 On
:
Close relay #1. Relay will automatically open when
unit becomes disarmed
Relay #1 Off
:
Open relay #1
Relay #2 On
:
Close relay #2. Relay will automatically open when
unit becomes disarmed
Relay #2 Off
:
Open relay #2
Relay #3 On
:
Close relay #3. Relay will automatically open when
unit becomes disarmed
Relay #3 Off
:
Open relay #3
Relay #4 On
:
Close relay #4. Relay will automatically open when
unit becomes disarmed
Relay #4 Off
:
Open relay #4
Relay Latch
IP100 uses Relay 1 and 2.
I-IPSIU uses Relays 1 through 4.
Relay #1 Latch
:
Close relay #1 until Master Reset or until a Relay
#1 Off is sent.
Relay #2 Latch
:
Close relay #2 until Master Reset or until a Relay
#2 Off is sent.
Relay #3 Latch
:
Close relay #3 until Master Reset or until a Relay
#3 Off is sent.
Relay #4 Latch
:
Close relay #4 until Master Reset or until a Relay
#4 Off is sent.