MSS
TM
Series
© Copyright 2022 Fluid Equipment Development Company | www.fedco-usa.com
-
34
-
Figure 67 -
Discharge Housing Alignment Pin
6.
Locate the discharge housing anti-rotation
pin on the bearing carrier and note the loca
-
tion of the discharge housing anti-rotation
pin hole.
Figure 66 -
Installing Cavity Cover
5.
Lubricate the cavity cover O-ring and install
the cavity cover.
NOTES:
Make sure to align throttle nipple
opening with the bottom of the pump.
Figure 65 -
Installing Balance Disc Washers
and Nut
APPLY SYSTEM COMPLIANT
ANTI-SEIZE COMPOUND
4. Apply system compliant anti-seize com-
pound onto the pump shaft threads and
install the balance disc washer, lock washer
and shaft nut. Tighten to torque value speci-
fied in the
Fastener Torque Specifications
section of this manual.
NOTES:
The pump shaft nut preload is critical
to proper balance disc operation. A properly
calibrated torque wrench must be used for this
step.
Pump Overhaul Continued